Abstract

PURPOSE OF REVIEW: Should ultrasound or nerve stimulation be used for brachial plexus blocks? We investigated last year's literature to help answer this question. RECENT
FINDINGS: Many of the reports concluded that ultrasound guidance may provide a higher success rate for brachial plexus blocks than guidance by nerve stimulator. However, the studies were not large enough to conclude that ultrasound will reduce the risk of nerve injury, local anesthetic toxicity or pneumothorax. Ultrasound may reveal anatomical variations of importance for performing brachial plexus blocks. For postoperative analgesia, 5 ml of ropivacaine 0.5% has been sufficient for an ultrasound-guided interscalene block. For peroperative anesthesia, as much as 42 ml of a local anesthetic mixture was calculated to be appropriate for an ultrasound-guided supraclavicular method. For the future, we notice that three-dimensional and four-dimensional ultrasound technology may facilitate visualizing the needle, the nerves and the local anesthetic distribution. Impedance measurements may be helpful for nerve blocks not guided by ultrasound.
SUMMARY: We think that the literature gives a sufficient basis to recommend the use of ultrasound for guidance of brachial plexus blocks. The potential for ultrasound to improve efficacy and reduce complications of brachial plexus blocks requires larger scaled studies.

Entities:  

Mesh:

Year:  2009        PMID: 19550303     DOI: 10.1097/ACO.0b013e32832eb7d3

Source DB:  PubMed          Journal:  Curr Opin Anaesthesiol        ISSN: 0952-7907            Impact factor:   2.706


  12 in total

1.  Detection of intraneural needle-placement with multiple frequency bioimpedance monitoring: a novel method.

Authors:  Håvard Kalvøy; Axel R Sauter
Journal:  J Clin Monit Comput       Date:  2015-04-23       Impact factor: 2.502

2.  A fluoroscopic assessment of brachial plexus block by the supraclavicular approach: Have we been overmedicating?

Authors:  Rashmi Datta; Jyotsna Agrawal; Gagan Narula; Bhavna Pahwa
Journal:  Med J Armed Forces India       Date:  2019-12-02

3.  Scalenus muscle and the C5 root of the brachial plexus: bilateral anatomical variation and its clinical significance.

Authors:  Gagandeep Kaur Aheer; Joey Villella
Journal:  J Can Chiropr Assoc       Date:  2021-08

4.  The success of periclavicular brachial plexus block.

Authors:  Jeong Uk Han
Journal:  Korean J Anesthesiol       Date:  2010-03-29

5.  Ultrasound estimates of muscle quality in older adults: reliability and comparison of Photoshop and ImageJ for the grayscale analysis of muscle echogenicity.

Authors:  Michael O Harris-Love; Bryant A Seamon; Carla Teixeira; Catheeja Ismail
Journal:  PeerJ       Date:  2016-02-22       Impact factor: 2.984

6.  The importance of needle echogenity in ultrasound guided axillary brachial plexus block: a randomized controlled clinical study.

Authors:  Cevdet Duger; Ahmet Cemil Isbir; Kenan Kaygusuz; Iclal Ozdemir Kol; Sinan Gursoy; Hayati Ozturk; Caner Mimaroğlu
Journal:  Int J Med Sci       Date:  2013-07-04       Impact factor: 3.738

7.  Pneumothorax following ultrasound guided supraclavicular brachial plexus block.

Authors:  Kapil Gupta; Shyam Bhandari; Deepak Singhal; Parminder S Bhatia
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2012-10

Review 8.  Brachial plexus injury as a complication after nerve block or vessel puncture.

Authors:  Hyun Jung Kim; Sang Hyun Park; Hye Young Shin; Yun Suk Choi
Journal:  Korean J Pain       Date:  2014-06-30

9.  Lack of Sex Difference in Minimum Local Analgesic Concentration of Ropivacaine for Ultrasound-Guided Supraclavicular Brachial Plexus Block.

Authors:  Qingqing Pei; Yanqing Yang; Qin Liu; Zhiyou Peng; Zhiying Feng
Journal:  Med Sci Monit       Date:  2015-11-11

10.  Comparison of ultrasound-guided and nerve stimulator-guided interscalene blocks as a sole anesthesia in shoulder arthroscopic rotator cuff repair: A retrospective study.

Authors:  Jung A Lim; Shin Yeung Sung; Ji Hyeon Lee; So Young Lee; Sang Gyu Kwak; Taeha Ryu; Woon Seok Roh
Journal:  Medicine (Baltimore)       Date:  2020-08-28       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.