| Literature DB >> 19549292 |
Thomas Mikeska1, Alexander Dobrovic.
Abstract
BACKGROUND: The development of reverse transcription - quantitative real-time PCR (RT-qPCR) platforms that can simultaneously measure the expression of multiple genes is dependent on robust assays that function under identical thermal cycling conditions. The use of a primer optimisation matrix to improve the performance of RT-qPCR assays is often recommended in technical bulletins and manuals. Despite this recommendation, a comprehensive introduction to and evaluation of this approach has been absent from the literature. Therefore, we investigated the impact of varying the primer concentration, leaving all the other reaction conditions unchanged, on a large number of RT-qPCR assays which in this case were designed to be monitored using hydrolysis probes from the Universal Probe Library (UPL) library.Entities:
Year: 2009 PMID: 19549292 PMCID: PMC2706253 DOI: 10.1186/1756-0500-2-112
Source DB: PubMed Journal: BMC Res Notes ISSN: 1756-0500
Figure 1Determining the optimum primer concentrations. (A) Distribution of the relative Cq differences (the difference between the primer combination showing the highest Cq value and the primer combination showing the lowest Cq value for each assay) obtained for each of the 60 RT-qPCR assays. (B) Distribution of the optimal primer concentration combinations for each of the 60 assays. The primer concentration combinations are given in nmol/L for the forward and the reverse primers respectively.
Figure 2RT-qPCR optimisation of the . (A) Amplification curves for the nine primer concentration combinations of the primer optimisation matrix. No amplification was seen for the no template controls (NTCs). The primer concentration combinations are indicated in the same colour as the corresponding curves. The mean Cq values and standard deviations (STD) were calculated from the amplification curves as outlined in Material and Methods. The primer concentration combinations are given in nmol/L for the forward and the reverse primer, respectively. (B) Digital image of NBS1 RT-qPCR reactions obtained for the primer optimisation matrix. Quality control of the RT-qPCR reactions by gel electrophoresis revealed only the NBS1 amplicon without additional, non-specific bands. The sizes of the molecular weight markers (MW) are given on the left, whereas the size of the NBS1 amplicon is indicated on the right (arrow). Wells loaded with RT-qPCR reactions are labelled with (+), while the respective no template control is labelled with (-). Sizes are given in base pairs and primer concentration combinations are given in nmol/L respectively.