Randomized controlled clinical study on the accuracy of two-stage putty-and-wash impression materials.

Manuela Haim1, Ralph G Luthardt, Heike Rudolph, Rainer Koch, Michael H Walter, Sebastian Quaas.   

Abstract

PURPOSE: The accuracy of dental impression taking is one major factor influencing the fit of crowns and fixed partial dentures. The aim of this study was to determine the accuracy of three-dimensional (3-D) tooth surface and subgingival tooth surface reproduction using three different silicone materials and the two-stage putty-and-wash technique.
MATERIALS AND METHODS: From 24 probands, three impressions each were taken with Express STD Putty/Wash (3M ESPE), Optosil/Xantopren L (Heraeus Kulzer), and an experimental ultralight body/putty material (3M ESPE) in a randomized order. The preliminary impression was cut according to established procedures for the two-stage putty-and-wash technique. Master casts were manufactured with a standardized procedure and optically digitized. The 3-D accuracy was analyzed with a computer-aided procedure. The Express STD putty-and-wash impressions were used as a reference. Linear models were used for the statistical analysis.
RESULTS: Mean deviations of 27.0 microm and -23.6 microm were found for Optosil/Xantopren L and 26.5 microm and -22.6 microm for the experimental material when analyzing 3-D surface reproduction. The tooth surface (buccal/oral) significantly influenced the accuracy of the surface reproduction. Optosil/Xantopren L showed a more complete reproduction of the subgingival tooth surface than either the experimental or reference materials.
CONCLUSION: The accuracy of the 3-D tooth surface reproduction as well as the reproduction of the subgingival tooth surface was not favorably influenced when the ultralight wash material was used with established cutting procedures for the preliminary impression.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19548415

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  4 in total

1.  Accuracy of digital models obtained by direct and indirect data capturing.

Authors:  Jan-Frederik Güth; Christine Keul; Michael Stimmelmayr; Florian Beuer; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-07-31       Impact factor: 3.573

2.  Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

Authors:  Heike Rudolph; Sebastian Quaas; Manuela Haim; Jörg Preißler; Michael H Walter; Rainer Koch; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2012-08-31       Impact factor: 3.573

3.  Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring.

Authors:  Stephania Caroline Rodolfo Silva; Aion Mangino Messias; Filipe de Oliveira Abi-Rached; Raphael Freitas de Souza; José Maurício Dos Santos Nunes Reis
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

4.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.