Literature DB >> 19545959

Mechanic effect of pulsed focused ultrasound in tumor and muscle tissue evaluated by MRI, histology, and microarray analysis.

Walter Hundt1, Esther L Yuh, Silke Steinbach, Mark D Bednarski, Samira Guccione.   

Abstract

The purpose of this study was to investigate the effect of pulsed high-intensity focused ultrasound (HIFU) to tumor and muscle tissue. Pulsed HIFU was applied to tumor and muscle tissue in C3H/Km mice. Three hours after HIFU treatment pre- and post-contrast T1-wt, T2-wt images and a diffusion-wt STEAM-sequence were obtained. After MR imaging, the animals were euthenized and the treated tumor and muscle was taken out for histology and functional genomic analysis. In the tumor tissue a slight increase of the diffusion coefficient could be found. In the muscle tissue T2 images showed increased signal intensity and post-contrast T1 showed a decreased contrast uptake in the center and a severe contrast uptake in the surrounding muscle tissue. A significant increase of the diffusion coefficient was found. Gene expression analysis revealed profound changes in the expression levels of 29 genes being up-regulated and 3 genes being down-regulated in the muscle tissue and 31 genes being up-regulated and 15 genes being down-regulated in the SCCVII tumor tissue. Seven genes were up-regulated in both tissue types. The highest up-regulated gene in the tumor and muscle tissue encoded for Mouse histone H2A.1 gene (FC=13.2±20.6) and Apolipoprotein E (FC=12.8±27.4) respectively MHC class III (FC=83.7±67.4) and hsp70 (FC=75.3±85.0). Immunoblot confirmed the presence of HSP70 protein in the muscle tissue. Pulsed HIFU treatment on tumor and muscle tissue results in dramatic changes in gene expression, indicating that the effect of pulsed HIFU is in some regard dependent and also independent of the tissue type.
Copyright © 2009. Published by Elsevier Ireland Ltd.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19545959     DOI: 10.1016/j.ejrad.2009.05.044

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  5 in total

Review 1.  MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics.

Authors:  Alberto Bazzocchi; Alessandro Napoli; Beatrice Sacconi; Giuseppe Battista; Giuseppe Guglielmi; Carlo Catalano; Ugo Albisinni
Journal:  Br J Radiol       Date:  2015-11-26       Impact factor: 3.039

2.  Quantitative evaluation of internal marks made using MRgFUS as seen on MRI, CT, US, and digital color images - a pilot study.

Authors:  Elizabeth Hipp; Xiaobing Fan; Ari Partanen; James Vosicky; Charles A Pelizzari; Christopher M Straus; Sham Sokka; Gregory S Karczmar
Journal:  Phys Med       Date:  2014-05-17       Impact factor: 2.685

3.  Ex vivo evaluation of high-intensity focused ultrasound with ultrasonic-induced cavitation bubbles.

Authors:  Nobutaka Abe; Hidekazu Nakamoto; Takashi Suzuki; Yoshihiro Muragaki; Hiroshi Iseki
Journal:  J Med Ultrason (2001)       Date:  2013-06-13       Impact factor: 1.314

4.  Estimation of thermal dose from MR thermometry during application of nonablative pulsed high intensity focused ultrasound.

Authors:  Brian E O'Neill; Christof Karmonik; Elisabetta Sassaroli; King C Li
Journal:  J Magn Reson Imaging       Date:  2011-12-14       Impact factor: 4.813

5.  Investigation of cellular and molecular responses to pulsed focused ultrasound in a mouse model.

Authors:  Scott R Burks; Ali Ziadloo; Hilary A Hancock; Aneeka Chaudhry; Dana D Dean; Bobbi K Lewis; Victor Frenkel; Joseph A Frank
Journal:  PLoS One       Date:  2011-09-13       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.