Efficacy of perflubutane microbubble-enhanced ultrasound in the characterization and detection of focal liver lesions: phase 3 multicenter clinical trial.

Fuminori Moriyasu1, Kouichi Itoh.   

Abstract

OBJECTIVE: The purpose of this study was to assess the efficacy and safety of contrast-enhanced ultrasound performed with perflubutane microbubbles in comparison with unenhanced ultrasound and dynamic CT in the characterization of focal liver lesions during the vascular phase of imaging and in the detection of lesions during the Kupffer phase. SUBJECTS AND METHODS: A total of 196 patients were enrolled at 15 centers in Japan. Vascular phase images were obtained before contrast injection until 1 minute after injection. Kupffer phase images were obtained 10 minutes after injection. Dual-phase CT was performed as determined by standard clinical practice at each center. Unenhanced ultrasound, contrast-enhanced ultrasound, and CT images were read by blinded reviewers, and the results they reached regarding characterization and detection were compared with reference standard findings made by onsite investigators. The safety observation period was 72 hours after contrast administration.
RESULTS: Among the 190 patients included in the characterization analysis, the accuracy of contrast-enhanced ultrasound (88.9%) was significantly greater than that of unenhanced ultrasound (68.4%) and dynamic CT (80.5%) (p < 0.001 and p = 0.008). Among the 191 patients in the detection analysis, the efficacy of contrast-enhanced ultrasound in detection of lesions was significantly higher than that of unenhanced ultrasound and dynamic CT (p < 0.001 and p = 0.008), predominantly because more metastatic lesions were detected (both p < 0.001). In particular, contrast-enhanced ultrasound was superior to dynamic CT in the detection of metastatic lesions measuring 1 cm or smaller. The incidence of adverse events was 49.2% and that of adverse drug reactions was 10.4%. All adverse drug reactions were mild.
CONCLUSION: Compared with unenhanced ultrasound and dynamic CT, contrast-enhanced ultrasound with perflubutane microbubbles improved diagnostic efficacy in both characterization and detection of focal liver lesions with no serious adverse drug reactions.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19542399     DOI: 10.2214/AJR.08.1618

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  50 in total

1.  Value of post-vascular phase (Kupffer imaging) by contrast-enhanced ultrasonography using Sonazoid in the detection of hepatocellular carcinoma.

Authors:  Eriko Goto; Ryota Masuzaki; Ryosuke Tateishi; Yuji Kondo; Jun Imamura; Tadashi Goto; Hitoshi Ikeda; Masaaki Akahane; Shuichiro Shiina; Masao Omata; Haruhiko Yoshida; Kazuhiko Koike
Journal:  J Gastroenterol       Date:  2011-12-27       Impact factor: 7.527

2.  Kupffer phase image of Sonazoid-enhanced US is useful in predicting a hypervascularization of non-hypervascular hypointense hepatic lesions detected on Gd-EOB-DTPA-enhanced MRI: a multicenter retrospective study.

Authors:  Tatsuo Inoue; Tomoko Hyodo; Keiko Korenaga; Takamichi Murakami; Yasuharu Imai; Atsushi Higaki; Takeshi Suda; Toru Takano; Kennichi Miyoshi; Masahiko Koda; Hironori Tanaka; Hiroko Iijima; Hironori Ochi; Masashi Hirooka; Kazushi Numata; Masatoshi Kudo
Journal:  J Gastroenterol       Date:  2015-09-15       Impact factor: 7.527

3.  Effect of obstructive jaundice on hepatic hemodynamics: use of Sonazoid-enhanced ultrasonography in a prospective study of the blood flow balance between the hepatic portal vein and hepatic artery.

Authors:  Noritaka Wakui; Yuki Takeda; Shuta Nishinakagawa; Nobuo Ueki; Takafumi Otsuka; Nobuyuki Oba; Hiroshi Hashimoto; Naohisa Kamiyama; Yasukiyo Sumino; Tatsuya Kojima
Journal:  J Med Ultrason (2001)       Date:  2015-04-08       Impact factor: 1.314

4.  Ability of contrast-enhanced ultrasonography to determine clinical responses of breast cancer to neoadjuvant chemotherapy.

Authors:  Ai Amioka; Norio Masumoto; Noriko Gouda; Keiko Kajitani; Hideo Shigematsu; Akiko Emi; Takayuki Kadoya; Morihito Okada
Journal:  Jpn J Clin Oncol       Date:  2016-02-03       Impact factor: 3.019

5.  A sub-centimeter HCC with bright loop appearance diagnosed by contrast-enhanced ultrasonography.

Authors:  Shuichi Sato; Tatsuya Miyake; Asako Fukuma; Eri Nitta; Noritsugu Yamashita; Takuya Hanaoka; Junichi Ishine; Hiroshi Tobita; Shuji Akagi; Yuji Amano; Yoshikazu Kinoshita
Journal:  J Med Ultrason (2001)       Date:  2010-11-27       Impact factor: 1.314

6.  A case of mucinous cystic neoplasm of the liver: description of Sonazoid-enhanced ultrasound imaging and histopathologic findings.

Authors:  Katsutoshi Sugimoto; Fuminori Moriyasu; Shin Kono; Motoko Sasaki; Yasuni Nakanuma; Yasuharu Imai
Journal:  J Med Ultrason (2001)       Date:  2012-12-05       Impact factor: 1.314

7.  Impact of splenic circulation: non-invasive microbubble-based assessment of portal hemodynamics.

Authors:  Taro Shimada; Hitoshi Maruyama; Takayuki Kondo; Tadashi Sekimoto; Masanori Takahashi; Osamu Yokosuka
Journal:  Eur Radiol       Date:  2014-11-01       Impact factor: 5.315

Review 8.  Functional imaging of hepatocellular carcinoma.

Authors:  Tim Ch Hoogenboom; Mark Thursz; Eric O Aboagye; Rohini Sharma
Journal:  Hepat Oncol       Date:  2016-03-29

9.  Irreversible electroporation for nonthermal tumor ablation in patients with hepatocellular carcinoma: initial clinical experience in Japan.

Authors:  Katsutoshi Sugimoto; Fuminori Moriyasu; Yoshiyuki Kobayashi; Kazuhiro Saito; Hirohito Takeuchi; Saori Ogawa; Mayumi Ando; Takatomo Sano; Toshifumi Mori; Yoshihiro Furuichi; Ikuo Nakamura
Journal:  Jpn J Radiol       Date:  2015-06-02       Impact factor: 2.374

Review 10.  Management of hepatocellular carcinoma: The role of contrast-enhanced ultrasound.

Authors:  Shu-Guang Zheng; Hui-Xiong Xu; Lin-Na Liu
Journal:  World J Radiol       Date:  2014-01-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.