Isolated locked compression plating for Vancouver Type B1 periprosthetic femoral fractures.

Ginger K Bryant1, Saam Morshed, Julie Agel, M Bradford Henley, David P Barei, Lisa A Taitsman, Sean E Nork.   

Abstract

OBJECTIVE: Report treatment results of periprosthetic femoral fractures adjacent or at the tip of a stable femoral stem (Vancouver Type B1) using a locked compression plate as the sole method of fracture stabilisation.
DESIGN: Retrospective case series.
SETTING: Academic Level I Trauma Centre. PATIENTS: Patients operatively treated at our institution with locked compression plating for Vancouver Type B1 periprosthetic fractures between 2002 and 2006 with at least 12 weeks of clinical follow-up were included. Patient demographics, hip arthroplasty implant characteristics, and AO/OTA fracture type were recorded. INTERVENTION: Open reduction internal fixation using a locked-plate spanning a majority of the femur through a lateral soft-tissue sparing approach. No cortical onlay allografts or cerclage devices (wires or cables) were used. MAIN OUTCOME MEASUREMENTS: Clinical union was defined at a minimum of 12 weeks as ability to walk, with or without the use of a walking aide, without pain at or around the fracture site. Radiographic union was defined by bridging bone spanning two or more cortices on orthogonal radiographs of the femur.
RESULTS: Ten subjects met the inclusion criteria and were followed for a mean of 27 weeks (range 14-97 weeks). All achieved fracture union at a mean of 17 weeks (range 12-27 weeks). There were no hardware failures or changes in fracture alignment from operative radiographs. There were no major complications that necessitated reoperation.
CONCLUSIONS: Open reduction internal fixation of Vancouver Type B1 periprosthetic femoral fractures using a lateral locked-plate that spans the full extent of the femur as the sole method of stabilisation is a successful treatment method that minimises soft-tissue dissection and provides adequate fixation strength to maintain fracture alignment to fracture union.

Entities:  

Mesh:

Year:  2009        PMID: 19539924     DOI: 10.1016/j.injury.2009.02.017

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  16 in total

Review 1.  In brief: classifications in brief: Vancouver classification of postoperative periprosthetic femur fractures.

Authors:  Greg E Gaski; Sean P Scully
Journal:  Clin Orthop Relat Res       Date:  2011-05       Impact factor: 4.176

2.  Biomechanics of periprosthetic femur fractures and early weightbearing.

Authors:  Ansab Khwaja; William Mahoney; Jay Johnson; Alex Trompeter; Jason Lowe
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-04-14

3.  Plate failure following plate osteosynthesis in periprosthetic femoral fractures.

Authors:  Sandra Boesmueller; Sebastian F Baumbach; Marcus Hofbauer; Gerald E Wozasek
Journal:  Wien Klin Wochenschr       Date:  2015-06-18       Impact factor: 1.704

4.  High union rates of locking compression plating with cortical strut allograft for type B1 periprosthetic femoral fractures.

Authors:  Ingwon Yeo; Kee-Hyung Rhyu; Sang-Min Kim; Yoon-Soo Park; Seung-Jae Lim
Journal:  Int Orthop       Date:  2016-01-13       Impact factor: 3.075

5.  Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable.

Authors:  Young-Soo Shin; Seung-Beom Han
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-01-16

6.  Postoperative periprosthetic fractures in patients with an Exeter stem due to a femoral neck fracture: cumulative incidence and surgical outcome.

Authors:  Christian Inngul; Anders Enocson
Journal:  Int Orthop       Date:  2014-10-24       Impact factor: 3.075

7.  Comparison of therapeutic outcomes of periprosthetic femoral fracture between treatments employing locking and conventional plates.

Authors:  Tomonori Baba; Kazuo Kaneko; Katsuo Shitoto; Kentaro Futamura; Yuichiro Maruyama
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-05-17

8.  Treatment results of a periprosthetic femoral fracture case series: treatment method for Vancouver type b2 fractures can be customized.

Authors:  Takahiro Niikura; Sang Yang Lee; Yoshitada Sakai; Kotaro Nishida; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Clin Orthop Surg       Date:  2014-05-16

9.  Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study.

Authors:  Gregory S Lewis; Cyrus T Caroom; Hwabok Wee; Darin Jurgensmeier; Shane D Rothermel; Michelle A Bramer; John Spence Reid
Journal:  J Orthop Trauma       Date:  2015-10       Impact factor: 2.512

10.  Clinical and radiological results of patients treated with orthogonal double plating for periprosthetic femoral fractures.

Authors:  Franz Josef Müller; Michael Galler; Bernd Füchtmeier
Journal:  Int Orthop       Date:  2014-08-12       Impact factor: 3.075