[Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique].

C Dos Remedios1, J Nebout, H Benlarbi, E Caremier, J-F Sam-Wing, R Beya.   

Abstract

INTRODUCTION: A surgical technique is described to preserve the pronator quadratus muscle when fixing distal radius fractures with volar locking palmar plates. TECHNIQUE: Using a classic volar Henry approach to the wrist, the fibrous distal attachments of the pronator quadratus muscle are released. The locking palmar plate is passed under the pronator quadratus muscle and its correct placement is checked by fluoroscopy. Locking screws are inserted through mini-incisions in pronator quadratus. DISCUSSION: The pronator quadratus muscle plays an important role in wrist function, both in forearm pronation and as a stabilizer of the distal radioulnar joint. Mechanical impingement between the volar plate and the flexor tendons can cause adherences, ruptures and tenosynovitis. These should be reduced if pronator quadratus were intact.
CONCLUSION: Preservation of the pronator quadratus muscle is possible for the majority of the fractures of the distal radius treated with locking volar plate osteosynthesis.

Entities:  

Mesh:

Year:  2009        PMID: 19539517     DOI: 10.1016/j.main.2009.04.007

Source DB:  PubMed          Journal:  Chir Main        ISSN: 1297-3203


  5 in total

1.  The cadaveric anatomy of the distal radius: implications for the use of volar plates.

Authors:  P A McCann; D Clarke; R Amirfeyz; R Bhatia
Journal:  Ann R Coll Surg Engl       Date:  2012-03       Impact factor: 1.891

2.  The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating.

Authors:  Zahab S Ahsan; Jeffrey Yao
Journal:  Hand (N Y)       Date:  2012-09

3.  Evaluation of sparing the pronator quadratus for volar plating of distal radius fractures: a retrospective clinical study.

Authors:  Xiaoxia Huang; Qiyu Jia; Huaqiang Li; Erxat Kerem; Cong Peng; Weiqi Kong; Maimaitiaili Tusunniyazi; Yimurang Hamiti; Dongwei Feng; Yan Zhao
Journal:  BMC Musculoskelet Disord       Date:  2022-06-30       Impact factor: 2.562

4.  Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures.

Authors:  Jae-Hwi Nho; Hyun Sik Gong; Cheol Ho Song; Seung Myung Wi; Young Ho Lee; Goo Hyun Baek
Journal:  Clin Orthop Surg       Date:  2014-08-05

5.  Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial.

Authors:  Sandra Häberle; Gunther Hubertus Sandmann; Stephan Deiler; Tobias Maximilian Kraus; Florian Fensky; Tobias Torsiglieri; Ina-Christine Rondak; Peter Biberthaler; Ulrich Stöckle; Sebastian Siebenlist
Journal:  Eur J Med Res       Date:  2015-11-25       Impact factor: 2.175