Literature DB >> 19537522

Pharmacokinetics and bioequivalence study of escitalopram oxalate formulations after single-dose administration in healthy Chinese male volunteers.

Jing Li1, Yuan Tian, Zun-Jian Zhang, Na Wang, Xiaolei Ren, Yun Chen.   

Abstract

The aim of the present study was to compare the bioavailability of escitalopram (CAS 128196-01-0) from two escitalopram oxalate (CAS 219861-08-2) tablets (escitalopram 10 mg tablet as test preparation and 10 mg tablet commercially available original tablet of the drug as reference preparation) in 20 Chinese healthy male volunteers, aged between 19 and 27. The study was conducted according to an open, randomized, single blind, 2-way crossover study design with a wash-out phase of 14 d. Blood samples for pharmacokinetic profiling were taken up to 156 h post-dose, and escitalopram plasma concentrations were determined with a validated liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method. Maximum plasma concentrations (C(max)) of 9.85 +/- 1.79 ng/ml (test) and 9.92 +/- 2.14 ng/ml (reference) were achieved. Areas under the plasma concentration-time curve (AUC(0-infinity)) of 428.40 +/- 140.25 ng x h/ml (test) and 413.73 +/- 144.81 ng x h/ml (reference), AUC(0-t) of 401.33 +/- 120.61 ng x h/ml (test), 385.42 +/- 117.73 ng x h/ml (reference) were calculated. The median T(max) was 4.3 +/- 1.8h, 4.1 +/- 1.5 h for test and reference formulation, respectively. Plasma elimination half-lives (t 1/2) of 36.30 +/- 8.93 h (test), 36.70 +/- 9.99 h (reference) were determined. Both primary target parameters, AUC(0-infinity) and AUC(0-t) were tested parametrically by analysis of variance (ANOVA) and relative bioavailabilities were 105.1 +/- 10.8% for AUC(0-infinity), 104.9 +/- 11.1% for AUC(0-t). Bioequivalence between test and reference preparation was demonstrated for both parameters, AUC(0-infinity) and AUC(0-t). The 90% confidence intervals of the T/R-ratios of logarithmically transformed data were in the generally accepted range of 80%-125%. That means that the test formulation is bioequivalent to the reference formulation for escitalopram.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19537522     DOI: 10.1055/s-0031-1296389

Source DB:  PubMed          Journal:  Arzneimittelforschung        ISSN: 0004-4172


  2 in total

1.  Determination of atomoxetine or escitalopram in human plasma by HPLC: Applications in neuroscience research studies
.

Authors:  Jens Teichert; James B Rowe; Karen D Ersche; Nikolina Skandali; Julia Sacher; Achim Aigner; Ralf Regenthal
Journal:  Int J Clin Pharmacol Ther       Date:  2020-08       Impact factor: 1.366

2.  Comparison of Bioavailability and Bioequivalence of Generic and Brand Name Formulations of Escitalopram Oxalate Tablets in Healthy Chinese Population Under Fasting and Fed Conditions.

Authors:  Qiuying Li; Hua Huo; Wenli Hu; Yin Sui; Yunbiao Tang
Journal:  Drug Des Devel Ther       Date:  2020-11-24       Impact factor: 4.162

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.