Literature DB >> 19535301

Direct electron transfer of glucose oxidase immobilized in an ionic liquid reconstituted cellulose-carbon nanotube matrix.

Xuee Wu1, Feng Zhao, John R Varcoe, Alfred E Thumser, Claudio Avignone-Rossa, Robert C T Slade.   

Abstract

Conductive cellulose-multiwalled carbon nanotube (MWCNT) matrix with a porous structure and good biocompatibility has been prepared using a room temperature ionic liquid (1-ethyl-3-methylimidazolium acetate) as solvent. Glucose oxidase (GOx) was encapsulated in this matrix and thereby immobilized on a glassy carbon surface. The direct electron transfer and electrocatalysis of the encapsulated GOx has been investigated using cyclic voltammetry and chronoamperometry. The GOx exhibited a pair of stable, well defined and nearly symmetric reversible redox peaks. The experimental results also demonstrate that the immobilized GOx retains its biocatalytic activity toward the oxidation of glucose and therefore can be employed in a glucose biosensor. The results show that the bioelectrode modified by the cellulose-MWCNT matrix has potential for use in biosensors and other bioelectronics devices.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19535301     DOI: 10.1016/j.bioelechem.2009.05.008

Source DB:  PubMed          Journal:  Bioelectrochemistry        ISSN: 1567-5394            Impact factor:   5.373


  5 in total

Review 1.  Nanosensors and nanomaterials for monitoring glucose in diabetes.

Authors:  Kevin J Cash; Heather A Clark
Journal:  Trends Mol Med       Date:  2010-09-24       Impact factor: 11.951

Review 2.  Recent advances in polymeric materials used as electron mediators and immobilizing matrices in developing enzyme electrodes.

Authors:  Mambo Moyo; Jonathan O Okonkwo; Nana M Agyei
Journal:  Sensors (Basel)       Date:  2012-01-16       Impact factor: 3.576

3.  Fermentation based carbon nanotube multifunctional bionic composites.

Authors:  Luca Valentini; Silvia Bittolo Bon; Stefano Signetti; Manoj Tripathi; Erica Iacob; Nicola M Pugno
Journal:  Sci Rep       Date:  2016-06-09       Impact factor: 4.379

4.  Engineering the Stability of Nanozyme-Catalyzed Product for Colorimetric Logic Gate Operations.

Authors:  Lianlian Fu; Deshuai Yu; Dijuan Zou; Hao Qian; Youhui Lin
Journal:  Molecules       Date:  2021-10-27       Impact factor: 4.411

5.  Glucose biosensor based on a glassy carbon electrode modified with polythionine and multiwalled carbon nanotubes.

Authors:  Wenwei Tang; Lei Li; Lujun Wu; Jiemin Gong; Xinping Zeng
Journal:  PLoS One       Date:  2014-05-09       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.