Literature DB >> 19532650

Image-guided diffuse optical fluorescence tomography implemented with Laplacian-type regularization.

Scott C Davis, Hamid Dehghani, Jia Wang, Shudong Jiang, Brian W Pogue, Keith D Paulsen.   

Abstract

A promising method to incorporate tissue structural information into the reconstruction of diffusion-based fluorescence imaging is introduced. The method regularizes the inversion problem with a Laplacian-type matrix, which inherently smoothes pre-defined tissue, but allows discontinuities between adjacent regions. The technique is most appropriately used when fluorescence tomography is combined with structural imaging systems. Phantom and simulation studies were used to illustrate significant improvements in quantitative imaging and linearity of response with the new algorithm. Images of an inclusion containing the fluorophore Lutetium Texaphyrin (Lutex) embedded in a cylindrical phantom are more accurate than in situations where no structural information is available, and edge artifacts which are normally prevalent were almost entirely suppressed. Most importantly, spatial priors provided a higher degree of sensitivity and accuracy to fluorophore concentration, though both techniques suffer from image bias caused by excitation signal leakage. The use of spatial priors becomes essential for accurate recovery of fluorophore distributions in complex tissue volumes. Simulation studies revealed an inability of the "no-priors" imaging algorithm to recover Lutex fluorescence yield in domains derived from T1 weighted images of a human breast. The same domains were reconstructed accurately to within 75% of the true values using prior knowledge of the internal tissue structure. This algorithmic approach will be implemented in an MR-coupled fluorescence spectroscopic tomography system, using the MR images for the structural template and the fluorescence data for region quantification.

Entities:  

Year:  2007        PMID: 19532650     DOI: 10.1364/oe.15.004066

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  56 in total

1.  System development for high frequency ultrasound-guided fluorescence quantification of skin layers.

Authors:  Josiah D Gruber; Akshat Paliwal; Venkataramanan Krishnaswamy; Hamid Ghadyani; Michael Jermyn; Julie A O'Hara; Scott C Davis; Joanna S Kerley-Hamilton; Nicholas W Shworak; Edward V Maytin; Tayyaba Hasan; Brian W Pogue
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

2.  Implementation of a new scanning method for high-resolution fluorescence tomography using thermo-sensitive fluorescent agents.

Authors:  Farouk Nouizi; Tiffany C Kwong; Jaedu Cho; Yuting Lin; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Opt Lett       Date:  2015-11-01       Impact factor: 3.776

3.  Spectrally resolved bioluminescence tomography using the reciprocity approach.

Authors:  Hamid Dehghani; Scott C Davis; Brian W Pogue
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

4.  Magnetic resonance-coupled fluorescence tomography scanner for molecular imaging of tissue.

Authors:  Scott C Davis; Brian W Pogue; Roger Springett; Christoph Leussler; Peter Mazurkewitz; Stephen B Tuttle; Summer L Gibbs-Strauss; Shudong S Jiang; Hamid Dehghani; Keith D Paulsen
Journal:  Rev Sci Instrum       Date:  2008-06       Impact factor: 1.523

5.  FMT-XCT: in vivo animal studies with hybrid fluorescence molecular tomography-X-ray computed tomography.

Authors:  Angelique Ale; Vladimir Ermolayev; Eva Herzog; Christian Cohrs; Martin Hrabé de Angelis; Vasilis Ntziachristos
Journal:  Nat Methods       Date:  2012-05-06       Impact factor: 28.547

6.  Fast segmentation and high-quality three-dimensional volume mesh creation from medical images for diffuse optical tomography.

Authors:  Michael Jermyn; Hamid Ghadyani; Michael A Mastanduno; Wes Turner; Scott C Davis; Hamid Dehghani; Brian W Pogue
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

7.  White light-informed optical properties improve ultrasound-guided fluorescence tomography of photoactive protoporphyrin IX.

Authors:  Brendan P Flynn; Alisha V DSouza; Stephen C Kanick; Scott C Davis; Brian W Pogue
Journal:  J Biomed Opt       Date:  2013-04       Impact factor: 3.170

8.  Combined fluorescence and X-Ray tomography for quantitative in vivo detection of fluorophore.

Authors:  W C Barber; Y Lin; O Nalcioglu; J S Iwanczyk; N E Hartsough; G Gulsen
Journal:  Technol Cancer Res Treat       Date:  2010-02

9.  Automatic exposure control and estimation of effective system noise in diffuse fluorescence tomography.

Authors:  Dax L Kepshire; Hamid Dehghani; Frederic Leblond; Brian W Pogue
Journal:  Opt Express       Date:  2009-12-07       Impact factor: 3.894

10.  Three-dimensional reconstruction in free-space whole-body fluorescence tomography of mice using optically reconstructed surface and atlas anatomy.

Authors:  Xiaofeng Zhang; Cristian T Badea; G Allan Johnson
Journal:  J Biomed Opt       Date:  2009 Nov-Dec       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.