Literature DB >> 19531887

Biosensors for phenolic compounds by immobilization of tyrosinase in photocurable methacrylic-acrylic membranes of varying hydrophilicities.

Sharina Abu Hanifah1, Lee Yook Heng, Musa Ahmad.   

Abstract

Electrochemical biosensors for phenolic compound determination were developed by immobilization of tyrosinase enzyme in a series of methacrylic-acrylic based biosensor membranes deposited directly using a photocuring method. By modifying the hydrophilicity of the membranes using different proportions of 2-hydroxyethyl methacrylate (HEMA) and butyl acrylate (nBA), we developed biosensor membranes of different hydrophilic characters. The differences in hydrophilicity of these membranes led to changes in the sensitivity of the biosensors towards different phenolic compounds. In general biosensors constructed from the methacrylic-acrylic based membranes showed the poorest response to catechol relative to other phenolic compounds, which is in contrast to many other biosensors based on tyrosinase. The decrease in hydrophilicity of the membrane also allowed better selectivity towards chlorophenols. However, phenol biosensors constructed from the more hydrophilic membrane materials demonstrated better analytical performance towards phenol compared with those made from less hydrophilic ones. For the detection of phenols, these biosensors with different membranes gave detection limits of 0.13-0.25 microM and linear response range from 6.2-54.2 microM phenol. The phenol biosensors also showed good phenol recovery from landfill leachate samples (82-117%).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19531887     DOI: 10.2116/analsci.25.779

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  3 in total

1.  An electrochemical study of acrylate bone adhesive permeability and selectivity change during in vitro ageing: A model approach to the study of biomaterials and membrane barriers.

Authors:  M Raja; J C Shelton; F Salamat-Zadeh; M Tavakoli; S Donell; G Watts; P Vadgama
Journal:  Anal Chim Acta X       Date:  2019-03-04

2.  Performance of a cyanobacteria whole cell-based fluorescence biosensor for heavy metal and pesticide detection.

Authors:  Wong Ling Shing; Lee Yook Heng; Salmijah Surif
Journal:  Sensors (Basel)       Date:  2013-05-14       Impact factor: 3.576

3.  An amperometric biosensor utilizing a ferrocene-mediated horseradish peroxidase reaction for the determination of capsaicin (chili hotness).

Authors:  Rosmawani Mohammad; Musa Ahmad; Lee Yook Heng
Journal:  Sensors (Basel)       Date:  2013-08-05       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.