Reconstructing uniformly attenuated rotating slant-hole SPECT projection data using the DBH method.

Qiu Huang1, Jingyan Xu, Benjamin M W Tsui, Grant T Gullberg.   

Abstract

This work applies a previously developed analytical algorithm to the reconstruction problem in a rotating multi-segment slant-hole (RMSSH) SPECT system. The RMSSH collimator has greater detection efficiency than the parallel-hole collimator with comparable spatial resolution at the expense of limited common volume-of-view (CVOV) and is therefore suitable for detecting low-contrast lesions in breast, cardiac and brain imaging. The absorption of gamma photons in both the human breast and brain can be assu- med to follow an exponential rule with a constant attenuation coefficient. In this work, the RMSSH SPECT data of a digital NCAT phantom with breast attachment are modeled as the uniformly attenuated Radon transform of the activity distribution. These data are reconstructed using an analytical algorithm called the DBH method, which is an acronym for the procedure of differentiation backprojection followed by a finite weighted inverse Hilbert transform. The projection data are first differentiated along a specific direction in the projection space and then backprojected to the image space. The result from this first step is equal to a one-dimensional finite weighted Hilbert transform of the object; this transform is then numerically inverted to obtain the reconstructed image. With the limited CVOV of the RMSSH collimator, the detector captures gamma photon emissions from the breast and from parts of the torso. The simulation results show that the DBH method is capable of exactly reconstructing the activity within a well-defined region-of-interest (ROI) within the breast if the activity is confined to the breast or if the activity outside the CVOV is uniformly attenuated for each measured projection, while a conventional filtered backprojection algorithm only reconstructs the high frequency components of the activity function in the same geometry.

Entities:  

Mesh:

Year:  2009        PMID: 19531850      PMCID: PMC2871256          DOI: 10.1088/0031-9155/54/13/024

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Exact inversion of the exponential x-ray transform for rotating slant-hole (RSH) SPECT.

Authors:  J M Wagner; F Noo; R Clackdoyle
Journal:  Phys Med Biol       Date:  2002-08-07       Impact factor: 3.609

2.  A two-step Hilbert transform method for 2D image reconstruction.

Authors:  Frédéric Noo; Rolf Clackdoyle; Jed D Pack
Journal:  Phys Med Biol       Date:  2004-09-07       Impact factor: 3.609

3.  Attenuation correction for rotating multi-segment slant-hole SPECT in breast imaging.

Authors:  Jingyan Xu; Chi Liu; Yuchuan C Wang; Eric C Frey; Benjamin M V Tsui
Journal:  Phys Med       Date:  2006       Impact factor: 2.685

4.  Ectomography. A new radiographic method for reproducing a selected slice of varying thickness.

Authors:  P Edholm; G Granlund; H Knutsson; C Petersson
Journal:  Acta Radiol Diagn (Stockh)       Date:  1980

5.  A simplified technique for measuring right ventricular ejection fraction using the equilibrium radionuclide angiocardiogram and the slant-hole collimator.

Authors:  B L Holman; J Wynne; J S Zielonka; J D Idoine
Journal:  Radiology       Date:  1981-02       Impact factor: 11.105

6.  Ectomography--a tomographic method for gamma camera imaging.

Authors:  S Dale; P E Edholm; L G Hellström; S Larsson
Journal:  Phys Med Biol       Date:  1985-11       Impact factor: 3.609

7.  Reconstruction from uniformly attenuated SPECT projection data using the DBH method.

Authors:  Qiu Huang; Jiangsheng You; Gengsheng L Zeng; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2009-01       Impact factor: 10.048

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.