Literature DB >> 19530686

Simultaneous determination by APCI-LC/MS/MS of hydroxylated and methoxylated polybrominated diphenyl ethers found in marine biota.

Yoshihisa Kato1, Syohei Okada, Kazutaka Atobe, Tetsuya Endo, Futoshi Matsubara, Takayoshi Oguma, Koichi Haraguchi.   

Abstract

A method has been developed for the simultaneous analysis of hydroxylated and methoxylated analogs of tetrabromodiphenyl ethers (OH-tetraBDEs and MeO-tetraBDEs) and of hydroxylated and methoxylated analogs of tetrabromobiphenyl (diOH-tetraBB and diMeO-tetraBB) using high performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (APCI-LC/MS/MS) in negative ion mode. Chromatographic separation was performed on a 150 mm ODS column with acetonitrile:water (9:1, v/v) in mobile phase. Multiple reaction monitoring (MRM) was performed using the precursor [M-H]- ion for hydroxylated analogs, and the [M-Br+O]- ion for tetraBDEs and tetraBB, and their methoxylated analogs. The method was validated using cod liver oil samples spiked with nine analytes (100 ng/g) for linearity (r2 > 0.998), recovery (75-95%), repeatability (8-36% RSD), and sensitivity (limits of quantification (LOQ), 0.1-0.25 ng/g lipid for phenolic analytes and 6-80 ng/g lipid for neutral brominated compounds). The APCI-LC/MS/MS was applied to analyze tiger shark and bull shark liver samples, where their concentrations were up to 8 ng/g (lipid weight) for OH-BDEs, whereas they were up to 540 ng/g (lipid weight) for MeO-BDEs. The results were consistent with values determined by electron ionization (EI)-GC/MS. The first detection of 2,2'-dihydroxy-3,3',5,5'-tetrabromobiphenyl (2,2'-diOH-BB80) by this method was in marine sponge from Micronesia. The advantage of the LC/MS/MS method over GC/MS is that it provides rapid and simultaneous determination of OH-BDEs, MeO-BDEs, and their related analogs with a single preparation step and without the involvement of chemical derivatives. Although the method provides the different LOQ ranges between hydroxylated and neutral brominated analogs, future work could apply the method to the full range of PBDE-like contaminants present in the environment and in biota tissues.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19530686     DOI: 10.1021/ac9009885

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Comprehensive two-dimensional separation of hydroxylated polybrominated diphenyl ethers by ultra-performance liquid chromatography coupled with ion mobility-mass spectrometry.

Authors:  Qiang Ma; Chao Wang; Hua Bai; Hai-Wei Xi; Guang-Cheng Xi; Xiao-Min Ren; Yu Yang; Liang-Hong Guo
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-16       Impact factor: 3.109

2.  Isomer Separation of Polybrominated Diphenyl Ether Metabolites using nanoESI-TIMS-MS.

Authors:  Kendra J Adams; Dennise Montero; Diana Aga; Francisco Fernandez-Lima
Journal:  Int J Ion Mobil Spectrom       Date:  2016-04-21

3.  "One-shot" analysis of polybrominated diphenyl ethers and their hydroxylated and methoxylated analogs in human breast milk and serum using gas chromatography-tandem mass spectrometry.

Authors:  Deena M Butryn; Michael S Gross; Lai-Har Chi; Arnold Schecter; James R Olson; Diana S Aga
Journal:  Anal Chim Acta       Date:  2015-08-25       Impact factor: 6.558

Review 4.  Advances in Instrumental Analysis of Brominated Flame Retardants: Current Status and Future Perspectives.

Authors:  Mohamed Abou-Elwafa Abdallah
Journal:  Int Sch Res Notices       Date:  2014-10-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.