Literature DB >> 19528838

Validation of the CardioCoachCO2 for submaximal and maximal metabolic exercise testing.

Christina M Dieli-Conwright1, Nicole E Jensky, Gina M Battaglia, Scott A McCauley, E Todd Schroeder.   

Abstract

This study examined the validity of the CardioCoachCO2 metabolic system to measure oxygen capacity by comparison to a previously validated device. Fourteen subjects (8 men and 6 women; 25.9 +/- 6.6 years of age) completed 2 maximal graded exercise tests on a cycle ergometer. Subjects were randomly tested on the CardioCoachCO2 and Medical Graphics CardiO2/CP (MedGraphics) system on 2 separate visits. The exercise test included 3 submaximal 3-minute stages (50, 75, and 100 W for women; 50, 100, and 150 W for men) followed by incremental, 25 W, 1-minute stages until volitional fatigue (Vo2max). There was no significant difference between the CardioCoachCO2 and MedGraphics except at the 100 W stage (22.4 +/- 4.8 and 20.3 +/- 3.7 ml x kg(-1) x min(-1), p = 0.048, respectively). Spearman correlations demonstrated a strong correlation between the 2 devices at maximal Vo2 (R = 0.94). Bland-Altman plots demonstrated small limits of agreement, indicating that the 2 devices are similar in measuring oxygen consumption. This study indicates that the CardioCoachCO2 is a valid device for testing Vo2 at submaximal and maximal levels. Validation of this device supports the CardioCoachCO2 as a feasible and convenient method for testing participants and may be useful in the field or clinic.

Entities:  

Mesh:

Year:  2009        PMID: 19528838     DOI: 10.1519/JSC.0b013e3181a3c5e8

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  3 in total

1.  Accuracy of peak VO2 assessments in career firefighters.

Authors:  Dana C Drew-Nord; Jonathan Myers; Stephen R Nord; Roberta K Oka; Oisaeng Hong; Erika S Froelicher
Journal:  J Occup Med Toxicol       Date:  2011-09-25       Impact factor: 2.646

2.  A Description and Comparison of Cardiorespiratory Fitness Measures in Relation to Pitching Performance Among Professional Baseball Pitchers.

Authors:  Javair S Gillett; J Jay Dawes; Frank J Spaniol; Matthew R Rhea; Joe P Rogowski; Mitchel A Magrini; Roberto Simao; Derek J Bunker
Journal:  Sports (Basel)       Date:  2016-02-25

3.  Phytoplankton Supplementation Lowers Muscle Damage and Sustains Performance across Repeated Exercise Bouts in Humans and Improves Antioxidant Capacity in a Mechanistic Animal.

Authors:  Matthew Sharp; Kazim Sahin; Matthew Stefan; Cemal Orhan; Raad Gheith; Dallen Reber; Nurhan Sahin; Mehmet Tuzcu; Ryan Lowery; Shane Durkee; Jacob Wilson
Journal:  Nutrients       Date:  2020-07-04       Impact factor: 5.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.