The precautionary principle: what is the risk of reusing disposable drops in routine ophthalmology consultations and what are the costs of reducing this risk to zero?

J E A Somner1, D J Cavanagh, K K Y Wong, M Whitelaw, T Thomson, D Mansfield.   

Abstract

BACKGROUND: Instilling eye drops is a ubiquitous procedure in eye clinics. This audit aimed to assess the risk of contamination of disposable droppers and to quantify the financial and waste implications of reducing this risk to zero by using disposable droppers only once.
METHODS: A total of 100 disposable Minims were used to place one drop in each eye of 70 patients. The dropper tip was then cultured for aerobic and anaerobic microbes.
RESULTS: Coagulase-negative staphylococcus was cultured from five samples. The contamination rate per drop application was 2.5%. The risk of cross-contamination with coagulase-negative staphylococcus would be between 1 : 400 and 1 : 80 if the bottle was reused once or six times. Reducing this risk to zero costs between pound2.75 and pound4.6 million per annum and generates between 6.85 and 11.42 more tonnes of paper waste and between 12.69 and 21.15 more tonnes of plastic waste than a strategy that reuses the disposable dropper.
CONCLUSION: Reducing the risk of dropper contamination and subsequent cross infection has financial and environmental costs. As exposure to coagulase-negative staphylococcus is not necessarily associated with infection, it would be useful to decide acceptable risk levels for a given cost to maximise both cost-effectiveness and patient safety.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19521427     DOI: 10.1038/eye.2009.129

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  3 in total

1.  Slit lamps and lenses: a potential source of nosocomial infections?

Authors:  Bianka Sobolewska; Michael Buhl; Jan Liese; Focke Ziemssen
Journal:  Eye (Lond)       Date:  2018-01-30       Impact factor: 3.775

2.  Microbial Cross-contamination in Multidose Eyedrops: The Impact of Instillation Angle and Bottle Geometry.

Authors:  Alexandre Xavier da Costa; Maria Cecilia Zorat Yu; Denise de Freitas; Priscila Cardoso Cristovam; Lauren C LaMonica; Vagner Rogerio Dos Santos; José Alvaro Pereira Gomes
Journal:  Transl Vis Sci Technol       Date:  2020-06-05       Impact factor: 3.283

3.  Microbial Contamination of Extended Use Ophthalmic Drops in Ophthalmology Clinic.

Authors:  Shee Wen Chua; Mushawiahti Mustapha; Kon Ken Wong; Malisa Ami; Aida Zairani Mohd Zahidin; Rona Asnida Nasaruddin
Journal:  Clin Ophthalmol       Date:  2021-07-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.