Literature DB >> 19520623

Measurement of serotonin in platelet depleted plasma by liquid chromatography tandem mass spectrometry.

Phillip J Monaghan1, Heather A Brown, Lesley A Houghton, Brian G Keevil.   

Abstract

5-Hydroxytryptamine (5-HT) in human platelet depleted plasma (PDP) is a biomarker in functional gastrointestinal disorders (FGID), with levels reflecting acute changes in circulating 5-HT concentration. PDP 5-HT is currently measured by reversed phase high performance liquid chromatography (HPLC) fluorimetric detection. We have developed a simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method that is two times more rapid than the current HPLC methodology. Our method employs a simple protein precipitation requiring no further downstream sample preparation. 10 microL of extract was injected directly onto a SecurityGuard SCX cation exchange column followed by isocratic elution onto an Onyx Monolithic C18 analytical column and methanolic gradient elution. Eluant was connected directly to a Quattro Premier XE tandem mass spectrometer operating in ES+ mode. We detected multiple reaction monitoring transitions m/z 160>114.9 and m/z 164.1>118.9 for 5-HT and d(4)-5-HT, respectively. 5-HT and d(4)-5-HT co-eluted at 2.79 min and cycle time between injections was 6 min. Mean recovery was 98%, limit of detection 1.5 nmol/L, lower limit of quantification 5 nmol/L, linearity to 1000 nmol/L (r(2)=0.999), imprecision <10% and bias <13.4%. 5-HT eluted with no ion suppression. No interference was found with l-tryptophan or 5-hydroxyindoleacetic acid (5-HIAA). This assay was compared to a previously published HPLC method. Passing-Bablok regression analysis showed LC-MS/MS=0.91 (HPLC)-0.83, r(2)=0.97, n=80. Bland Altman analysis showed general agreement, with a mean bias of 3.3 nmol/L. We have developed a simple and robust assay for PDP 5-HT that will increase throughput for clinical trials.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19520623     DOI: 10.1016/j.jchromb.2009.05.045

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

Review 1.  Serotonin and blood pressure regulation.

Authors:  Stephanie W Watts; Shaun F Morrison; Robert Patrick Davis; Susan M Barman
Journal:  Pharmacol Rev       Date:  2012-03-08       Impact factor: 25.468

2.  5-HT causes splanchnic venodilation.

Authors:  Bridget M Seitz; Hakan S Orer; Teresa Krieger-Burke; Emma S Darios; Janice M Thompson; Gregory D Fink; Stephanie W Watts
Journal:  Am J Physiol Heart Circ Physiol       Date:  2017-06-16       Impact factor: 4.733

Review 3.  Oh, the places you'll go! My many colored serotonin (apologies to Dr. Seuss).

Authors:  Stephanie W Watts
Journal:  Am J Physiol Heart Circ Physiol       Date:  2016-09-23       Impact factor: 4.733

4.  Recent Advances in Mass Spectrometry for the Identification of Neuro-chemicals and their Metabolites in Biofluids.

Authors:  Suresh Kumar Kailasa; Hui-Fen Wu
Journal:  Curr Neuropharmacol       Date:  2013-07       Impact factor: 7.363

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.