BACKGROUND: Previous studies have identified a substantial prevalence of a blood pressure difference between arms in various populations, but not patients with type 2 diabetes. Recognition of such a difference would be important as a potential cause of underestimation of blood pressure. AIM: To measure prevalence of an inter-arm blood pressure difference in patients with type 2 diabetes, and to estimate how frequently blood pressure measurements could be erroneously underestimated if an inter-arm difference is unrecognised. DESIGN OF STUDY: Cross-sectional study. SETTING: Five surgeries covered by three general practices, Devon, England. METHOD: Patients with type 2 diabetes underwent bilateral simultaneous blood pressure measurements using a validated protocol. Mean blood pressures were calculated for each arm to derive mean systolic and diastolic differences, and to estimate point prevalence of predefined magnitudes of difference. RESULTS: A total of 101 participants were recruited. Mean age was 66 years (standard deviation [SD] = 13.9 years); 59% were male, and mean blood pressure was 138/79 mmHg (SD = 15/10 mmHg). Ten participants (10%; 95% confidence interval [CI] = 4 to 16) had a systolic inter-arm difference > or =10 mmHg; 29 (29%; 95% CI = 20 to 38) had a diastolic difference >/=5 mmHg; and three (3%; 95% CI = 0 to 6) a diastolic difference > or =10 mmHg. No confounding variable was observed to account for the magnitude of an inter-arm difference. CONCLUSION: A systolic inter-arm difference > or =10 mmHg was observed in 10% of patients with diabetes. Failure to recognise this would misclassify half of these as normotensive rather than hypertensive using the lower-reading arm. New patients with type 2 diabetes should be screened for an inter-arm blood pressure difference.
BACKGROUND: Previous studies have identified a substantial prevalence of a blood pressure difference between arms in various populations, but not patients with type 2 diabetes. Recognition of such a difference would be important as a potential cause of underestimation of blood pressure. AIM: To measure prevalence of an inter-arm blood pressure difference in patients with type 2 diabetes, and to estimate how frequently blood pressure measurements could be erroneously underestimated if an inter-arm difference is unrecognised. DESIGN OF STUDY: Cross-sectional study. SETTING: Five surgeries covered by three general practices, Devon, England. METHOD:Patients with type 2 diabetes underwent bilateral simultaneous blood pressure measurements using a validated protocol. Mean blood pressures were calculated for each arm to derive mean systolic and diastolic differences, and to estimate point prevalence of predefined magnitudes of difference. RESULTS: A total of 101 participants were recruited. Mean age was 66 years (standard deviation [SD] = 13.9 years); 59% were male, and mean blood pressure was 138/79 mmHg (SD = 15/10 mmHg). Ten participants (10%; 95% confidence interval [CI] = 4 to 16) had a systolic inter-arm difference > or =10 mmHg; 29 (29%; 95% CI = 20 to 38) had a diastolic difference >/=5 mmHg; and three (3%; 95% CI = 0 to 6) a diastolic difference > or =10 mmHg. No confounding variable was observed to account for the magnitude of an inter-arm difference. CONCLUSION: A systolic inter-arm difference > or =10 mmHg was observed in 10% of patients with diabetes. Failure to recognise this would misclassify half of these as normotensive rather than hypertensive using the lower-reading arm. New patients with type 2 diabetes should be screened for an inter-arm blood pressure difference.
Authors: B Williams; N R Poulter; M J Brown; M Davis; G T McInnes; J F Potter; P S Sever; S McG Thom Journal: J Hum Hypertens Date: 2004-03 Impact factor: 3.012
Authors: Victor Aboyans; Michael H Criqui; Mary McGrae McDermott; Matthew A Allison; Julie O Denenberg; Ramin Shadman; Arnost Fronek Journal: J Am Coll Cardiol Date: 2007-03-26 Impact factor: 24.094
Authors: Ido Weinberg; Philimon Gona; Christopher J O'Donnell; Michael R Jaff; Joanne M Murabito Journal: Am J Med Date: 2013-11-25 Impact factor: 4.965
Authors: James White; Laust H Mortensen; Mika Kivimäki; Catharine R Gale; G David Batty Journal: Eur J Prev Cardiol Date: 2013-07-01 Impact factor: 7.804
Authors: Christopher E Clark; Kate Boddy; Fiona C Warren; Rod S Taylor; Victor Aboyans; Lyne Cloutier; Richard J McManus; Angela C Shore; John L Campbell Journal: BMJ Open Date: 2017-07-02 Impact factor: 2.692