Quantitative real-time PCR tests for diagnostic and prognostic purposes in cases of legionellosis.

M Maurin1, L Hammer, B Gestin, J F Timsit, O Rogeaux, F Delavena, J Tous, O Epaulard, J P Brion, J Croizé.   

Abstract

The usefulness of two quantitative real-time PCR assays (qrt-PCRmip targeting Legionella pneumophila, and qrt-PCR16S targeting all Legionella species) performed on lower respiratory tract (LRT) samples for diagnostic and prognostic purposes in 311 patients hospitalized for community-acquired pneumonia (CAP) in Rhône-Alpes (France) was evaluated. The Now Legionella urinary antigen test (UAT) from Binax (Portland, ME, USA) was used as a reference test. Samples were divided into two groups. Group A included 255 CAP patients admitted to Chambery hospital in 2005 and 2006. The Now Legionella UAT was positive in 14 patients. Sensitivities, specificities, positive predictive and negative predictive values for both qrt-PCR tests were 63.6, 98.7, 77.7 and 97.4%, respectively. Group B included 56 consecutive legionellosis patients diagnosed during a 4-year period (2003-2006) at the Grenoble University Hospital. The qrt-PCR16S and qrt-PCRmip displayed a sensitivity of 82.14 and 80.4%, respectively. Among the 70 legionellosis cases, L. pneumophila serogroup 1 was isolated in 15; qrt-PCRmip was positive in another 36, suggesting L. pneumophila infection, whereas the Legionella species involved could not be determined in the remaining 19 cases. The Legionella burden in LRT samples at the time of admission was determined in 46 patients using qrt-PCR16S tests, 44 for qrt-PCR mip groups A and B patients. It varied from 1.9 to 8.35 log(10) DNA copies/mL of LRT sample for qrt-PCR16S and from 1.9 to 8.11 log(10) DNA copies/mL of sample for qrt-PCRmip. High bacterial loads in LRT samples at hospital admission were significantly associated with higher Fine classes, the need for hospitalization in an intensive care unit and for prolonged hospitalization.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19519843     DOI: 10.1111/j.1469-0691.2009.02812.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  16 in total

1.  Guidelines for the management of adult lower respiratory tract infections--full version.

Authors:  M Woodhead; F Blasi; S Ewig; J Garau; G Huchon; M Ieven; A Ortqvist; T Schaberg; A Torres; G van der Heijden; R Read; T J M Verheij
Journal:  Clin Microbiol Infect       Date:  2011-11       Impact factor: 8.067

2.  PCR method for the rapid detection and discrimination of Legionella spp. based on the amplification of pcs, pmtA, and 16S rRNA genes.

Authors:  Monika Janczarek; Marta Palusińska-Szysz
Journal:  J Appl Genet       Date:  2015-09-30       Impact factor: 3.240

3.  Application of Legionella pneumophila-specific quantitative real-time PCR combined with direct amplification and sequence-based typing in the diagnosis and epidemiological investigation of Legionnaires' disease.

Authors:  M Mentasti; N K Fry; B Afshar; C Palepou-Foxley; F C Naik; T G Harrison
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-01-26       Impact factor: 3.267

Review 4.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

5.  Ribosomal Mutations Conferring Macrolide Resistance in Legionella pneumophila.

Authors:  Ghislaine Descours; Christophe Ginevra; Nathalie Jacotin; Françoise Forey; Joëlle Chastang; Elisabeth Kay; Jerome Etienne; Gérard Lina; Patricia Doublet; Sophie Jarraud
Journal:  Antimicrob Agents Chemother       Date:  2017-02-23       Impact factor: 5.191

Review 6.  Diagnostic Accuracy of PCR Alone and Compared to Urinary Antigen Testing for Detection of Legionella spp.: a Systematic Review.

Authors:  Tomer Avni; Amir Bieber; Hefziba Green; Tali Steinmetz; Leonard Leibovici; Mical Paul
Journal:  J Clin Microbiol       Date:  2015-12-09       Impact factor: 5.948

7.  Digital PCR for Detection and Quantification of Fluoroquinolone Resistance in Legionella pneumophila.

Authors:  Aurélie Hennebique; Marie Bidart; Sophie Jarraud; Laëtitia Beraud; Carole Schwebel; Max Maurin; Sandrine Boisset
Journal:  Antimicrob Agents Chemother       Date:  2017-08-24       Impact factor: 5.191

8.  Clinical application of a multiplex real-time PCR assay for simultaneous detection of Legionella species, Legionella pneumophila, and Legionella pneumophila serogroup 1.

Authors:  Alvaro J Benitez; Jonas M Winchell
Journal:  J Clin Microbiol       Date:  2012-11-07       Impact factor: 5.948

9.  Association between faecal load of lawsonia intracellularis and pathological findings of proliferative enteropathy in pigs with diarrhoea.

Authors:  Ken Steen Pedersen; Marie Ståhl; Roberto Maurício Carvalho Guedes; Øystein Angen; Jens Peter Nielsen; Tim K Jensen
Journal:  BMC Vet Res       Date:  2012-10-23       Impact factor: 2.741

10.  Legionellosis and lung abscesses: contribution of legionella quantitative real-time PCR to an adapted followup.

Authors:  G Descours; C Tellini; C Flamens; F Philit; M Celard; J Etienne; G Lina; S Jarraud
Journal:  Case Rep Infect Dis       Date:  2013-06-03