Assessment of acetone as an alternative to acetonitrile in peptide analysis by liquid chromatography/mass spectrometry.

Ria Fritz1, Wolfgang Ruth, Udo Kragl.   

Abstract

Acetonitrile as a solvent used in liquid chromatography/mass spectrometry (LC/MS) of peptides and proteins is a relatively toxic solvent (LD50 oral; rat; 2,460 mg/kg) compared to alternatives like methanol (LD50 oral; rat; 5,628 mg/kg) and acetone (LD50 oral; rat; 5,800 mg/kg). Strategies to minimize its consumption in LC are either to reduce the inner diameter of the column or replace acetonitrile with a suitable alternative. Methanol is often recommended to replace acetonitrile in peptide analysis. In this study however, the main focus lies on another alternative solvent for LC/MS of peptides; acetone. A number of model proteins were tryptically digested and the peptide solutions were analyzed on a linear trap quadrupole (LTQ) mass spectrometer. The performances of acetonitrile, methanol and acetone were compared according to the quality of the chromatograms obtained and identification of the peptides using the BioWorks software developed by Thermo Scientific. In accordance to the elutropic series, acetone was found to significantly reduce the retention times of peptides separated by C18 column material with regard to acetonitrile while methanol led to increased retention times. Acetone was the superior solvent to methanol for most of the tested model proteins reaching similar sequence coverage and numbers of identified peptides as acetonitrile. We therefore propose acetone as an alternative to acetonitrile in LC/MS of peptides. Copyright 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19517463     DOI: 10.1002/rcm.4122

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  A nano-chip-LC/MSn based strategy for characterization of modified nucleosides using reduced porous graphitic carbon as a stationary phase.

Authors:  Anders Michael Bernth Giessing; Lincoln Greyson Scott; Finn Kirpekar
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-15       Impact factor: 3.109

Review 2.  Greening Reversed-Phase Liquid Chromatography Methods Using Alternative Solvents for Pharmaceutical Analysis.

Authors:  Moussa Yabré; Ludivine Ferey; Issa Touridomon Somé; Karen Gaudin
Journal:  Molecules       Date:  2018-05-02       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.