Literature DB >> 19515182

Patient-directed titration for achieving glycaemic goals using a once-daily basal insulin analogue: an assessment of two different fasting plasma glucose targets - the TITRATE study.

L Blonde1, M Merilainen, V Karwe, P Raskin.   

Abstract

AIMS: To compare efficacy and safety of two fasting plasma glucose (FPG) titration targets [4.4-6.1 mmol/l (80-110 mg/dl) and 3.9-5.0 mmol/l (70-90 mg/dl)] using a patient-directed, treat-to-target algorithm for once-daily basal insulin in insulin-naïve subjects with type 2 diabetes suboptimally treated with oral antidiabetes drugs (OADs).
METHODS: In this 20-week, randomized, controlled, open-label, multicentre, treat-to-target study, 244 insulin-naïve subjects with type 2 diabetes, HbA(1c)>or=7.0 and <or=9.0% on OAD treatment, were randomized (1 : 1) to one of two treatment arms using 3.9-5.0 or 4.4-6.1 mmol/l FPG as titration targets. Once-daily insulin detemir doses were adjusted using algorithm-guided patient-directed titration to achieve target FPG values.
RESULTS: Overall, the combined treatment groups achieved a mean HbA(1c) level of 6.9% at the end of the study. Substantial reductions in HbA(1c) were seen in both treatment groups, with the majority of subjects in both titration groups at the end of the study achieving the American Diabetes Association (ADA)-recommended HbA(1c) level of <7%. In the 3.9-5.0 mmol/l FPG target treatment group, HbA(1c) values decreased from a baseline mean of 8.0% to 6.8% at 20 weeks. In the 4.4-6.1 mmol/l FPG target group, HbA(1c) values decreased from 7.9% at baseline to 7.0% at 20 weeks (Intention to treat - last observation carried forward data set). These decreases were significantly different between the two treatment groups (Least squares mean difference = -0.271, 95% CI -0.441 to -0.101, p = 0.0019), favouring the FPG target of 3.9-5.0 mmol/l vs. the 4.4-6.1 mmol/l target. At the end of the study period, 64.3% of subjects in the 3.9-5.0 mmol/l treatment group achieved HbA(1c) levels <7% compared with 54.5% of subjects in the 4.4-6.1 mmol/l group (95% CI 1.03-3.37, odds ratio 1.86, p = 0.04). Insulin detemir dosing patterns were similar between treatment groups, with the 3.9-5.0 mmol/l group using slightly greater doses throughout the study period (0.57 U/kg vs. 0.51 U/kg at the end of the study). Overall rates of hypoglycaemia episodes were low and were comparable between treatment groups (7.73 and 5.27 events/subject/year for the 3.9-5.0 and 4.4-6.1 mmol/l groups, respectively). A single event of major hypoglycaemia was reported in the 3.9-5.0 mmol/l group. Mean weight changes from baseline to the end of the study were small and did not differ significantly between treatment groups.
CONCLUSIONS: The 3.9-5.0 mmol/l FPG target showed superior efficacy compared with the 4.4-6.1 mmol/l target, although both FPG titration targets resulted in substantial reductions of HbA(1c) in patients with type 2 diabetes using a patient-directed insulin titration algorithm. A majority of subjects in both titration groups achieved the ADA-recommended guideline of <7% HbA(1c) at the end of the study with low rates of hypoglycaemia. These data indicate that lowering the fasting glucose target using a self-directed titration algorithm with once-daily detemir is safe and increases the likelihood of achieving the target level of HbA(1c). Indeed, using this approach, a majority of patients can achieve an HbA(1c) of <7%.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19515182     DOI: 10.1111/j.1463-1326.2009.01060.x

Source DB:  PubMed          Journal:  Diabetes Obes Metab        ISSN: 1462-8902            Impact factor:   6.577


  57 in total

Review 1.  Standards of medical care in diabetes--2012.

Authors: 
Journal:  Diabetes Care       Date:  2012-01       Impact factor: 19.112

2.  Response to Swinnen et al.

Authors:  Alan C Moses; Christoph Koenen
Journal:  Diabetes Technol Ther       Date:  2010-06       Impact factor: 6.118

3.  Standards of medical care in diabetes--2011.

Authors: 
Journal:  Diabetes Care       Date:  2011-01       Impact factor: 19.112

4.  Standards of medical care in diabetes--2010.

Authors: 
Journal:  Diabetes Care       Date:  2010-01       Impact factor: 19.112

5.  Standards of medical care in diabetes--2013.

Authors: 
Journal:  Diabetes Care       Date:  2013-01       Impact factor: 19.112

6.  Self-monitoring of blood glucose: a prerequisite for diabetes management in outcome trials.

Authors:  Oliver Schnell; Markolf Hanefeld; Louis Monnier
Journal:  J Diabetes Sci Technol       Date:  2014-04-02

7.  Conventional and Alternative Mesenchymal Stem Cell Therapies for the Treatment of Diabetes.

Authors:  Lubna Rifai; Fatima A Saleh
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

8.  Are analogue insulins superior to human insulin in clinical practice?

Authors:  Jeffrey S Freeman
Journal:  Curr Diab Rep       Date:  2010-06       Impact factor: 4.810

9.  Clinical Considerations for Insulin Pharmacotherapy in Ambulatory Care, Part One: Introduction and Review of Current Products and Guidelines.

Authors:  John A Galdo; Maria Miller Thurston; Catherine A Bourg
Journal:  Clin Diabetes       Date:  2014-04

Review 10.  How pharmacokinetic and pharmacodynamic principles pave the way for optimal basal insulin therapy in type 2 diabetes.

Authors:  S Arnolds; B Kuglin; C Kapitza; T Heise
Journal:  Int J Clin Pract       Date:  2010-07-05       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.