Literature DB >> 19512874

Venous air embolism during total laparoscopic hysterectomy: comparison to total abdominal hysterectomy.

Chang Seok Kim1, Ji Young Kim, Ja-Young Kwon, Seung Ho Choi, Sungwon Na, Jiwon An, Ki Jun Kim.   

Abstract

BACKGROUND: Total laparoscopic hysterectomy (TLH) has become a widely accepted alternative to total abdominal hysterectomy (TAH). The aim of this study was to compare the incidence and grade of venous air embolism (VAE) in TLH to those in TAH using transesophageal echocardiography.
METHODS: Eighty-two American Society of Anesthesiologists physical status I patients scheduled for either TLH or TAH were enrolled. After induction of general anesthesia, a multiplane transesophageal echocardiography probe was inserted. The midesophageal four-chamber or bicaval view was continuously monitored. An independent transesophageal echocardiography-certified anesthesiologist graded VAE.
RESULTS: All patients undergoing TLH showed VAE, and 37.5% of patients had VAE grade higher than III. Fifteen percent of patients undergoing TAH showed VAE, and all of them were grade I. No patient in this study showed hemodynamic instability or electrocardiogram changes at the time of VAE occurrence. Most instances of VAE during TLH occurred during transection of the round ligament and dissection of the broad ligament.
CONCLUSION: The incidence of VAE in patients undergoing TLH was 100%. VAE grade in TLH was higher compared to that in TAH, especially during transection of the round ligament and dissection of the broad ligament. Although the hemodynamic instability associated with VAE during TLH was not observed in this study, anesthesiologists must be vigilant for detection of VAE during TLH.

Entities:  

Mesh:

Year:  2009        PMID: 19512874     DOI: 10.1097/ALN.0b013e3181a05ac7

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  11 in total

1.  Air in the insufflation tube may cause fatal embolizations in laparoscopic surgery: an animal study.

Authors:  Steffen Richter; Christine Matthes; Till Ploenes; Devrim Aksakal; Tobias Wowra; Thomas Hückstädt; Felix Schier; Christoph Kampmann
Journal:  Surg Endosc       Date:  2012-12-13       Impact factor: 4.584

2.  Seesawing end-tidal carbon dioxide: portent of critical carbon dioxide embolism in retroperitoneoscopy.

Authors:  Melvin Alex Abraham; Riya Jose; Mazhuvanchary Jacob Paul
Journal:  BMJ Case Rep       Date:  2018-01-23

Review 3.  [Intraoperative vascular air embolism : Evidence for risks, diagnostics and treatment].

Authors:  P Michels; E C Meyer; I F Brandes; A Bräuer
Journal:  Anaesthesist       Date:  2021-05       Impact factor: 1.041

Review 4.  Carbon dioxide embolism during laparoscopic surgery.

Authors:  Eun Young Park; Ja-Young Kwon; Ki Jun Kim
Journal:  Yonsei Med J       Date:  2012-05       Impact factor: 2.759

5.  Transient Left-Sided Paralysis following Robotic-Assisted Laparoscopic Uteropexy.

Authors:  Jasmina Kurdija; Jan G Jakobsson
Journal:  Case Rep Anesthesiol       Date:  2015-05-26

6.  Paradoxical carbon dioxide embolism during laparoscopic hepatectomy without intracardiac shunt: A case report.

Authors:  Soeun Jeon; Jeong-Min Hong; Hyeon Jeong Lee; Yesul Kim; Hyunjong Kang; Boo-Young Hwang; Dowon Lee; Young-Hoon Jung
Journal:  World J Clin Cases       Date:  2022-03-26       Impact factor: 1.337

Review 7.  Complications of Transoral Thyroidectomy: Overview and Update.

Authors:  Kyung Tae
Journal:  Clin Exp Otorhinolaryngol       Date:  2020-11-19       Impact factor: 3.372

8.  Incidence of venous air embolism during myomectomy: the effect of patient position.

Authors:  Jiwon An; Seo Kyung Shin; Ja-Young Kwon; Ki Jun Kim
Journal:  Yonsei Med J       Date:  2013-01-01       Impact factor: 2.759

Review 9.  Paradoxical carbon dioxide embolism during laparoscopic surgery without intracardiac right-to-left shunt: two case reports and a brief review of the literature.

Authors:  Wenting Hou; Jing Zhong; Bo Pan; Jiapeng Huang; Biyu Wang; Zhirong Sun; Changhong Miao
Journal:  J Int Med Res       Date:  2020-08       Impact factor: 1.671

10.  The AirSeal® insufflation device can entrain room air during routine operation.

Authors:  R P Weenink; M Kloosterman; R Hompes; P J Zondervan; H P Beerlage; P J Tanis; R A van Hulst
Journal:  Tech Coloproctol       Date:  2020-07-30       Impact factor: 3.781

View more