Effects of clinical recycling on mechanical properties of nickel-titanium alloy wires.

S Kapila1, G W Reichhold, R S Anderson, L G Watanabe.   

Abstract

The purpose of this investigation was to determine the effects of clinical recycling on the load-deflection characteristics and the surface topography of nickel-titanium alloy wires. Thirty wires each of Nitinol and NiTi were subjected to a three-point bending test in an as-received condition (T0) and after clinical exposure of one cycle (T1) and two cycles (T2). Ten wires made up the sample at each of these time points. One cycle was defined as 8 weeks, plus or minus 1 week, of clinical use. Wires undergoing two recycles were cold sterilized after their first clinical exposure. Statistical analyses were done by one-factor repeated measures ANOVA and Scheffe F test. Recycling produced significant changes in both the loading and unloading characteristics of NiTi wires, but only with the loading forces associated with nitinol wires. Representative scanning electron micrographs demonstrated increased pitting of both nitinol and NiTi wires. Several areas were also observed to be smoothened on nitinol wires and scored on NiTi wires.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1951195     DOI: 10.1016/0889-5406(91)70082-8

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  6 in total

1.  Evaluation of Mechanical and Physical Properties of Clinically Used and Recycled Superelastic NiTi Wires.

Authors:  Venkata Naidu Bavikati; Gowri Sankar Singaraju; Prasad Mandava; Sai Sandeep Killamsetty; Venkatesh Nettam; Praveen Kumar Reddy Karnati
Journal:  J Clin Diagn Res       Date:  2016-07-01

2.  Torsional superelasticity of NiTi archwires.

Authors:  Yves Bolender; Anne Vernière; Christophe Rapin; Marie-Pierryle Filleul
Journal:  Angle Orthod       Date:  2010-11       Impact factor: 2.079

3.  Effect of immersion in hydrochloric acid and sodium hypochlorite and autoclave sterilization on the force characteristics of orthodontic nickel-titanium open coils.

Authors:  Saeed Noorollahian; Mehrnaz Zakizade
Journal:  Dent Res J (Isfahan)       Date:  2021-02-23

4.  Impact of recycling on the mechanical properties of nickel-titanium alloy wires and the efficacy of their reuse after cold sterilization.

Authors:  Ankit Yadav; Poonam K Jayaprakash; Rajeshwar Singh; Meeta Dawer; Palash Modi; Bhumika Sehdev; Kiran K Ganji
Journal:  J Orthod Sci       Date:  2020-08-18

5.  Effect of Recycling and Autoclave Sterilization on the Unloading Forces of NiTi Closed-Coil Springs: An In Vitro Study.

Authors:  Sh Momeni Danaei; M Oshagh; A Khozaei
Journal:  J Dent (Shiraz)       Date:  2013-12

6.  Evaluation of tensile strength and surface topography of orthodontic wires after infection control procedures: An in vitro study.

Authors:  M Brindha; N Kurunji Kumaran; K Rajasigamani
Journal:  J Pharm Bioallied Sci       Date:  2014-07