Literature DB >> 1951120

Effects of increased heart rate and sympathetic tone on intraventricular electrogram morphology.

C J Finelli1, L A DiCarlo, J M Jenkins, S A Winston, P C Li.   

Abstract

Electrogram pattern recognition by way of morphologic analysis has been proposed as a technique that may improve discrimination of ventricular tachycardia from sinus rhythm by antitachycardia devices. The potential impact that increases in heart rate and sympathetic tone could have on such techniques, however, has not been previously determined. A comparative study was undertaken to quantify possible changes in ventricular electrogram morphology using correlation waveform, area of difference, and amplitude analyses in 6 patients during atrial overdrive pacing at cycle lengths of 600 and 400 ms (group A), in 13 patients during infusions of physiologic doses of epinephrine (group B), and in 20 patients undergoing infusions of isoproterenol (group C). Four patients were in both groups A and B. A bipolar intraventricular template of cardiac depolarization during sinus rhythm at rest was compared with depolarization during subsequent passages of sinus rhythm at rest and subsequently increased heart rate. In 36 of 39 patients, waveform configuration as assessed by correlation waveform analysis remained relatively stable during atrial overdrive pacing, epinephrine infusion, and isoproterenol infusion when compared with sinus rhythm at rest. The correlation value did not fall below 0.950 in any patient. Area of difference values for the same 36 patients changed by an average of 6 and 37% during atrial overdrive pacing at cycle lengths of 600 and 400 ms intervals, respectively, by 3% during epinephrine infusion, and by 17% during isoproterenol infusion. In these same patients, there was an average change in electrogram amplitude of -1% during atrial overdrive pacing at 600 ms, 26% during pacing at 400 ms, -1% during epinephrine infusion, and 12% during isoproterenol infusion.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1951120     DOI: 10.1016/0002-9149(91)90239-h

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Testing of a new T-wave subtraction algorithm as an aid to localizing ectopic atrial beats.

Authors:  John P Marenco; Hiroshi Nakagawa; Shawn Yang; David MacAdam; Lucien Xu; Ding S He; Mark S Link; Munther K Homoud; N A Mark Estes III; Paul J Wang
Journal:  Ann Noninvasive Electrocardiol       Date:  2003-01       Impact factor: 1.468

2.  A pilot study examining the performance of polynomial-modeled ventricular shock electrograms for rhythm discrimination in implantable devices.

Authors:  Jeffrey L Williams; Vladimir Shusterman; Samir Saba
Journal:  Pacing Clin Electrophysiol       Date:  2006-09       Impact factor: 1.976

3.  A segmental polynomial model of ventricular electrograms as a simple and efficient morphology discriminator for implantable devices.

Authors:  Jeffrey L Williams; Vladimir Shusterman; Samir Saba
Journal:  Ann Noninvasive Electrocardiol       Date:  2006-07       Impact factor: 1.468

4.  Identification of recurring patterns in fractionated atrial electrograms using new transform coefficients.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; Hasan Garan
Journal:  Biomed Eng Online       Date:  2012-01-19       Impact factor: 2.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.