Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source.

Julia Herzen1, Tilman Donath, Franz Pfeiffer, Oliver Bunk, Celestino Padeste, Felix Beckmann, Andreas Schreyer, Christian David.   

Abstract

Over the last few years, differential phase-contrast x-ray computed tomography (PC-CT) using a hard x-ray grating interferometer and polychromatic x-ray tube sources has been developed. The method allows for simultaneous determination of the attenuation coefficient and the refractive index decrement distribution inside an object in three dimensions. Here we report experimental results of our investigation on the quantitativeness and accuracy of this method. For this study, a phantom consisting of several tubes filled with chemically well-defined liquids was built and measured in PC-CT. We find, that the measured attenuation coefficients and refractive index decrements closely match calculated, theoretical values. Moreover, the study demonstrates, how substances with similar attenuation coefficient or refractive index decrement, can be uniquely distinguished by the simultaneous, quantitative measurement of both quantities.

Mesh:

Substances:

Year:  2009        PMID: 19506651     DOI: 10.1364/oe.17.010010

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  27 in total

1.  Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT.

Authors:  Joseph Zambelli; Nicholas Bevins; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Experimental results from a preclinical X-ray phase-contrast CT scanner.

Authors:  Arne Tapfer; Martin Bech; Astrid Velroyen; Jan Meiser; Jürgen Mohr; Marco Walter; Joachim Schulz; Bart Pauwels; Peter Bruyndonckx; Xuan Liu; Alexander Sasov; Franz Pfeiffer
Journal:  Proc Natl Acad Sci U S A       Date:  2012-09-10       Impact factor: 11.205

3.  X-ray phase-contrast imaging of the breast--advances towards clinical implementation.

Authors:  S D Auweter; J Herzen; M Willner; S Grandl; K Scherer; F Bamberg; M F Reiser; F Pfeiffer; K Hellerhoff
Journal:  Br J Radiol       Date:  2014-02       Impact factor: 3.039

4.  Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography.

Authors:  Guang-Hong Chen; Joseph Zambelli; Ke Li; Nicholas Bevins; Zhihua Qi
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

5.  X-ray phase-contrast tomography with a compact laser-driven synchrotron source.

Authors:  Elena Eggl; Simone Schleede; Martin Bech; Klaus Achterhold; Roderick Loewen; Ronald D Ruth; Franz Pfeiffer
Journal:  Proc Natl Acad Sci U S A       Date:  2015-04-20       Impact factor: 11.205

Review 6.  Assessment of grating-based X-ray phase-contrast CT for differentiation of invasive ductal carcinoma and ductal carcinoma in situ in an experimental ex vivo set-up.

Authors:  Anikó Sztrókay; Julia Herzen; Sigrid D Auweter; Susanne Liebhardt; Doris Mayr; Marian Willner; Dieter Hahn; Irene Zanette; Timm Weitkamp; Karin Hellerhoff; Franz Pfeiffer; Maximilian F Reiser; Fabian Bamberg
Journal:  Eur Radiol       Date:  2012-08-31       Impact factor: 5.315

7.  Interior tomography in x-ray differential phase contrast CT imaging.

Authors:  Pascal Thériault Lauzier; Zhihua Qi; Joseph Zambelli; Nicholas Bevins; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

8.  Diagnosing and mapping pulmonary emphysema on X-ray projection images: incremental value of grating-based X-ray dark-field imaging.

Authors:  Felix G Meinel; Felix Schwab; Simone Schleede; Martin Bech; Julia Herzen; Klaus Achterhold; Sigrid Auweter; Fabian Bamberg; Ali Ö Yildirim; Alexander Bohla; Oliver Eickelberg; Rod Loewen; Martin Gifford; Ronald Ruth; Maximilian F Reiser; Franz Pfeiffer; Konstantin Nikolaou
Journal:  PLoS One       Date:  2013-03-26       Impact factor: 3.240

Review 9.  [Phase contrast imaging of the breast. Basic principles and steps towards clinical implementation].

Authors:  S Grandl; A Sztrókay-Gaul; S D Auweter; K Hellerhoff
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

Review 10.  Edge-illumination x-ray phase-contrast imaging.

Authors:  Alessandro Olivo
Journal:  J Phys Condens Matter       Date:  2021-07-13       Impact factor: 2.333