Literature DB >> 19506096

Pulse wave velocity assessment by external noninvasive devices and phase-contrast magnetic resonance imaging in the obese.

Laure Joly1, Christine Perret-Guillaume, Anna Kearney-Schwartz, Paolo Salvi, Damien Mandry, Pierre-Yves Marie, Gilles Karcher, Patrick Rossignol, Faiez Zannad, Athanase Benetos.   

Abstract

Carotid-femoral pulse wave velocity (PWV) is considered the gold-standard measurement of arterial stiffness. Obesity, however, can render inaccurate the measurement of PWV by external noninvasive devices. Phase-contrast MRI allows the determination of aortic PWV in multiple aortic locations with intra-arterial distance measurements, as well as the assessment of aortic mechanical properties. The purpose of this study was to assess the reliability of external carotid-femoral PWV values measured by well-validated external devices in comparison with MRI acquisitions of PWV and aortic mechanical properties in a population of obese subjects. PWV was measured with PulsePen and Complior II devices in 32 volunteers (18 men and 14 women), aged 46 to 65 years (mean: 55.7+/-5.1 years), presenting with isolated abdominal obesity, with a waist circumference >102 cm for men and >88 cm for women, and a body mass index between 27 and 35. These results were then compared with MRI PWV values and cross-sectional MRI thoracic aorta distensibility values. MRI PWV values were positively correlated with PWV measured by both PulsePen (r=0.47; P=0.005) and Complior (r=0.43; P=0.01). Aortic cross-sectional stiffness was positively correlated with PulsePen PWV (r=0.42; P=0.02). The same trend was also observed with Complior PWV (r=0.33; P=0.06). This is the first study comparing transcutaneous PWV measurements with MRI aortic elastic properties in obese subjects. Our results indicate that, for body mass index values < or =35 kg m(-2), PWV measured externally with Complior or PulsePen validly reflect values obtained directly in the thoracic aorta through MRI.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19506096     DOI: 10.1161/HYPERTENSIONAHA.109.133645

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  26 in total

Review 1.  Imaging Insights on the Aorta in Aging.

Authors:  Yoshiaki Ohyama; Alban Redheuil; Nadjia Kachenoura; Bharath Ambale Venkatesh; Joao A C Lima
Journal:  Circ Cardiovasc Imaging       Date:  2018-04       Impact factor: 7.792

2.  Oscillometric assessment of arterial stiffness in everyday clinical practice.

Authors:  Alexander Reshetnik; Christopher Gohlisch; Markus Tölle; Walter Zidek; Markus Van Der Giet
Journal:  Hypertens Res       Date:  2016-09-08       Impact factor: 3.872

3.  Influence of Thoracic Aortic Inflammation and Calcifications on Arterial Stiffness and Cardiac Function in Older Subjects.

Authors:  L Joly; D Mandry; A Verger; C Labat; G Watfa; V Roux; G Karcher; P-Y Marie; A Benetos
Journal:  J Nutr Health Aging       Date:  2016-03       Impact factor: 4.075

4.  Cardiovascular correlates of insulin resistance in normotensive and hypertensive African Americans.

Authors:  Srividya Kidambi; Jane M Kotchen; Shanthi Krishnaswami; Clarence E Grim; Theodore A Kotchen
Journal:  Metabolism       Date:  2010-09-16       Impact factor: 8.694

5.  Acute effects of sauna bathing on cardiovascular function.

Authors:  Tanjaniina Laukkanen; Setor K Kunutsor; Francesco Zaccardi; Earric Lee; Peter Willeit; Hassan Khan; Jari A Laukkanen
Journal:  J Hum Hypertens       Date:  2017-12-21       Impact factor: 3.012

6.  Long-term effects of a renin inhibitor versus a thiazide diuretic on arterial stiffness and left ventricular diastolic function in elderly hypertensive patients.

Authors:  Yoshiyuki Okada; Shigeki Shibata; Naoki Fujimoto; Stuart A Best; Benjamin D Levine; Qi Fu
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2017-07-19       Impact factor: 3.619

7.  AORTIC PULSE WAVE VELOCITY MEASURED BY PULSE WAVE IMAGING (PWI): A COMPARISON WITH APPLANATION TONOMETRY.

Authors:  Jonathan Vappou; Jianwen Luo; Kazue Okajima; Marco Di Tullio; Elisa Konofagou
Journal:  Artery Res       Date:  2011-06-01       Impact factor: 0.597

8.  Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques.

Authors:  El-Sayed H Ibrahim; Kevin R Johnson; Alan B Miller; Jean M Shaffer; Richard D White
Journal:  J Cardiovasc Magn Reson       Date:  2010-05-11       Impact factor: 5.364

9.  Assessment of regional aortic stiffness with cardiac magnetic resonance imaging in a healthy Asian population.

Authors:  Eun Kyoung Kim; Sung-A Chang; Shin Yi Jang; Yiseul Kim; Sung Mok Kim; Jae K Oh; Yeon Hyeon Choe; Duk-Kyung Kim
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-17       Impact factor: 2.357

Review 10.  Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness.

Authors:  Andrew L Wentland; Thomas M Grist; Oliver Wieben
Journal:  Cardiovasc Diagn Ther       Date:  2014-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.