Literature DB >> 19499865

Sore throat or hoarse voice with bronchial blockers or double-lumen tubes for lung isolation: a randomised, prospective trial.

T Zhong1, W Wang, J Chen, L Ran, D A Story.   

Abstract

Double-lumen endotracheal tubes and bronchial blockers allow lung isolation for one-lung ventilation. Few studies, however, directly compare these devices. Further, a new endobronchial blocker (Coopdech) is available in some countries. Our primary hypothesis was that bronchial blockers would be associated with less sore throat or hoarse voice than double-lumen tubes. Secondary outcomes were successful one-lung ventilation and surgical access. In this prospective trial, 120 Chinese patients undergoing elective surgery were randomly assigned to one of four groups of 30 patients: Coopdech blocker, Arndt blocker Univent tube or double-lumen tube. Postoperative sore throat and hoarse voice were assessed in the recovery room and 24 hours after surgery. The incidence and severity of sore throat or hoarse voice was less in the blocker groups than double-lumen tube group: Coopdech 13%, Arndt 20%, Univent 30% and double-lumen tube 60%, P < 0.001. The blocker groups did not significantly differ P = 0.28. Compared to the double-lumen tubes the bronchial blockers took about two minutes less to position but five minutes longer for lung deflation. Surgical exposure was uniformly good across the four groups. We conclude that clinical use of the Coopdech endobronchial blocker is similar to the Arndt and Univent blockers and that all three are associated with less sore throat or hoarse voice than double-lumen tubes.

Entities:  

Mesh:

Year:  2009        PMID: 19499865

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  10 in total

1.  Non-intubated thoracoscopic bullectomy under sedation is safe and comfortable in the perioperative period.

Authors:  Jinwook Hwang; Jae Seung Shin; Joo Hyung Son; Too Jae Min
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

2.  Efficacy of a New Blind Insertion Technique of Arndt Endobronchial Blocker for Lung Isolation: Comparison With Conventional Bronchoscope-Guided Insertion Technique-A Pilot Study.

Authors:  Peng Liang; Juan Ni; Cheng Zhou; Hai Yu; Bin Liu
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

3.  A comparison of extraluminal and intraluminal use of the Uniblocker in left thoracic surgery: A CONSORT-compliant article.

Authors:  Zhuo Liu; WenSheng He; QianQian Jia; XiaoChun Yang; ShuJuan Liang; XiuLi Wang
Journal:  Medicine (Baltimore)       Date:  2017-05       Impact factor: 1.889

4.  The EZ-blocker for one-lung ventilation in patients undergoing thoracic surgery: clinical applications and experience in 100 cases in a routine clinical setting.

Authors:  Andreas Moritz; Andrea Irouschek; Torsten Birkholz; Johannes Prottengeier; Horia Sirbu; Joachim Schmidt
Journal:  J Cardiothorac Surg       Date:  2018-06-25       Impact factor: 1.637

5.  Comparison of different size left-sided double-lumen tubes for thoracic surgery.

Authors:  Raisa D Nguyen; Lakshmi N Kurnutala; Michelle A Tucci; Bryan J Hierlmeier
Journal:  Ann Card Anaesth       Date:  2021 Jan-Mar

6.  Efficacy and Safety of Video-Laryngoscopy versus Direct Laryngoscopy for Double-Lumen Endotracheal Intubation: A Systematic Review and Meta-Analysis.

Authors:  Katarzyna Karczewska; Szymon Bialka; Jacek Smereka; Maciej Cyran; Grazyna Nowak-Starz; Jaroslaw Chmielewski; Michal Pruc; Pawel Wieczorek; Frank William Peacock; Jerzy Robert Ladny; Lukasz Szarpak
Journal:  J Clin Med       Date:  2021-11-25       Impact factor: 4.241

7.  Comparison of left double lumen tube and y-shaped and double-ended bronchial blocker for one lung ventilation in thoracic surgery-a randomised controlled clinical trial.

Authors:  Joachim Risse; Karsten Szeder; Ann-Kristin Schubert; Thomas Wiesmann; Hanns-Christian Dinges; Carsten Feldmann; Hinnerk Wulf; Karl Matteo Meggiolaro
Journal:  BMC Anesthesiol       Date:  2022-04-02       Impact factor: 2.217

8.  Effect of postoperative ultrasound-guided internal superior laryngeal nerve block on sore throat after intubation of double-lumen bronchial tube: a randomized controlled double-blind trial.

Authors:  Jingxian Wang; Bin Chai; Yujie Zhang; Lidong Zheng; Pengcheng Geng; Li Zhan
Journal:  BMC Anesthesiol       Date:  2022-09-01       Impact factor: 2.376

9.  Videolaryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation in thoracic surgery - a randomised controlled clinical trial.

Authors:  Joachim Risse; Ann-Kristin Schubert; Thomas Wiesmann; Ansgar Huelshoff; David Stay; Michael Zentgraf; Andreas Kirschbaum; Hinnerk Wulf; Carsten Feldmann; Karl Matteo Meggiolaro
Journal:  BMC Anesthesiol       Date:  2020-06-16       Impact factor: 2.217

10.  Nonintubated minimally invasive chest wall stabilization for multiple rib fractures: a prospective, single-arm study.

Authors:  Weigang Zhao; Yonglin Chen; Weiwei He; Yonghong Zhao; Yi Yang
Journal:  World J Emerg Surg       Date:  2020-09-23       Impact factor: 5.469

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.