Literature DB >> 19498129

Evaluation of causes and frequency of medication errors during information technology downtime.

Tara L Hanuscak1, Sheryl L Szeinbach, Enrique Seoane-Vazquez, Brendan J Reichert, Charles F McCluskey.   

Abstract

PURPOSE: The causes and frequency of medication errors occurring during information technology downtime were evaluated.
METHODS: Individuals from a convenience sample of 78 hospitals who were directly responsible for supporting and maintaining clinical information systems (CISs) and automated dispensing systems (ADSs) were surveyed using an online tool between February 2007 and May 2007 to determine if medication errors were reported during periods of system downtime. The errors were classified using the National Coordinating Council for Medication Error Reporting and Prevention severity scoring index. The percentage of respondents reporting downtime was estimated.
RESULTS: Of the 78 eligible hospitals, 32 respondents with CIS and ADS responsibilities completed the online survey for a response rate of 41%. For computerized prescriber order entry, patch installations and system upgrades caused an average downtime of 57% over a 12-month period. Lost interface and interface malfunction were reported for centralized and decentralized ADSs, with an average downtime response of 34% and 29%, respectively. The average downtime response was 31% for software malfunctions linked to clinical decision-support systems. Although patient harm did not result from 30 (54%) medication errors, the potential for harm was present for 9 (16%) of these errors.
CONCLUSION: Medication errors occurred during CIS and ADS downtime despite the availability of backup systems and standard protocols to handle periods of system downtime. Efforts should be directed to reduce the frequency and length of down-time in order to minimize medication errors during such downtime.

Entities:  

Mesh:

Year:  2009        PMID: 19498129     DOI: 10.2146/ajhp080389

Source DB:  PubMed          Journal:  Am J Health Syst Pharm        ISSN: 1079-2082            Impact factor:   2.637


  3 in total

1.  Clinical impact of intraoperative electronic health record downtime on surgical patients.

Authors:  Andrew M Harrison; Rizwan Siwani; Brian W Pickering; Vitaly Herasevich
Journal:  J Am Med Inform Assoc       Date:  2019-10-01       Impact factor: 4.497

2.  Impact of technological innovation on a nursing home performance and on the medication-use process safety.

Authors:  Chantal Baril; Viviane Gascon; Christel Brouillette
Journal:  J Med Syst       Date:  2014-03-14       Impact factor: 4.460

3.  Implications of electronic health record downtime: an analysis of patient safety event reports.

Authors:  Ethan Larsen; Allan Fong; Christian Wernz; Raj M Ratwani
Journal:  J Am Med Inform Assoc       Date:  2018-02-01       Impact factor: 4.497

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.