In vivo evaluation of a mechanically oscillating dual-mode applicator for ultrasound imaging and thermal ablation.

Neil R Owen1, Guillaume Bouchoux, Belhassen Seket, Adriana Murillo-Rincon, Samir Merouche, Alain Birer, Christian Paquet, Eric Delabrousse, Jean-Yves Chapelon, Rémi Berriet, Gérard Fleury, Cyril Lafon.   

Abstract

Unresectable liver tumors are often treated with interstitial probes that modify tissue temperature, and efficacious treatment relies on image guidance for tissue targeting and assessment. Here, we report the in vivo evaluation of an interstitial applicator with a mechanically oscillating five-element dual-mode transducer. After thoroughly characterizing the transducer, tissue response to high-intensity ultrasound was numerically calculated to select parameters for experimentation in vivo. Using perfused porcine liver, B-mode sector images were formed before and after a 120-s therapy period, and M-mode imaging monitored the therapy axis during therapy. The time-averaged transducer surface intensity was 21 or 27 W/cm (2). Electroacoustic conversion efficiency was maximally 72 +/- 3% and impulse response length was 295 +/- 1.0 ns at -6 dB. The depth of thermal damage measured by gross histology ranged from 10 to 25 mm for 13 insertion sites. For six sites, M-mode data exhibited a reduction in gray-scale intensity that was interpreted as the temporal variation of coagulation necrosis. Contrast ratio analysis indicated that the gray-scale intensity dropped by 7.8 +/- 3.3 dB, and estimated the final lesion depth to an accuracy of 2.3 +/- 2.4 mm. This paper verified that the applicator could induce coagulation necrosis in perfused liver and demonstrated the feasibility of real-time monitoring.

Entities:  

Mesh:

Year:  2009        PMID: 19497808     DOI: 10.1109/TBME.2009.2023994

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  Miniaturized Intracavitary Forward-Looking Ultrasound Transducer for Tissue Ablation.

Authors:  Howuk Kim; Huaiyu Wu; Namwoo Cho; Pei Zhong; Kamran Mahmood; Herbert Kim Lyerly; Xiaoning Jiang
Journal:  IEEE Trans Biomed Eng       Date:  2019-11-22       Impact factor: 4.538

2.  Dual-focus therapeutic ultrasound transducer for production of broad tissue lesions.

Authors:  Jong Seob Jeong; Jonathan M Cannata; K Kirk Shung
Journal:  Ultrasound Med Biol       Date:  2010-09-27       Impact factor: 2.998

3.  Multiple applicator hepatic ablation with interstitial ultrasound devices: theoretical and experimental investigation.

Authors:  Punit Prakash; Vasant A Salgaonkar; E Clif Burdette; Chris J Diederich
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

4.  Considerations for theoretical modelling of thermal ablation with catheter-based ultrasonic sources: implications for treatment planning, monitoring and control.

Authors:  Punit Prakash; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

Review 5.  Catheter-based ultrasound technology for image-guided thermal therapy: current technology and applications.

Authors:  Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2015-03-23       Impact factor: 3.914

Review 6.  Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning.

Authors:  Punit Prakash; Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2013-06       Impact factor: 3.914