Literature DB >> 19497515

Patterns of procedure-specific radiation exposure in the endovascular era: impetus for further innovation.

Mohsen Bannazadeh1, Ozcan Altinel, Vikram S Kashyap, Zhiyuan Sun, Daniel Clair, Timur P Sarac.   

Abstract

OBJECTIVE: Although patient preference and outcome data support continued development and use of minimally invasive endovascular therapies, only a few studies have documented radiation exposure to the patient. This report summarizes patient radiation exposure by endovascular procedure at Cleveland Clinic.
METHODS: A retrospective review was undertaken of all endovascular procedures during a 30-month period. Procedures were categorized as infrarenal aortic aneurysm (IAA), isolated thoracic aneurysm (TA), visceral occlusive intervention, renal artery intervention, cerebrovascular intervention, cerebrovascular and lower extremity diagnostic, atherectomy, and lower extremity intervention. Radiation exposure was categorized by procedure. The estimated skin dose (ESD, mGy) and effective dose (ED, mSv) were calculated. Total computed tomography (CT) scans were tabulated for patients undergoing aneurysm stent grafting, and the cumulative ED was estimated. Statistical analyses were done with Kruskal-Wallis tests to detect overall differences, Wilcoxon rank sum exact tests for paired comparisons, and the Bonferroni post hoc test for group comparison.
RESULTS: Fluoroscopy times were recorded in 2103 endovascular procedures. The more complex the procedure, the longer the fluoroscopy time and ESD. Patients undergoing atherectomy had significantly higher ESD, at 1260 mGy (900, 1542; P < .001) than all groups. When converting to ED, however, cerebrovascular intervention and IAA received the highest ED, at 120 mSV (100, 150 mSV) and 109 mSV (85, 151 mSV; respectively, P < .001) among other groups. TAA patients underwent a greater number of CT scans than IAA patients (7.4 +/- 0.3 vs 5.8 +/- 0.2; P < .004). Tabulating the cumulative ED, including procedure and CT scans, showed IAA patients had significantly higher doses of radiation exposure than TAA patients (217 +/- 5 vs 191 +/- 6; P < .004).
CONCLUSIONS: The increasing complexity of endovascular interventions has resulted in increased radiation exposure to all involved, with the highest doses occurring in aneurysm repairs. Future innovations should concentrate on reducing the risk of radiation exposure to all personnel and developing newer imaging techniques.

Entities:  

Mesh:

Year:  2009        PMID: 19497515     DOI: 10.1016/j.jvs.2009.02.015

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  4 in total

Review 1.  Physician and Patient Radiation Exposure During Endovascular Procedures.

Authors:  Andrew M Goldsweig; J Dawn Abbott; Herbert D Aronow
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-02

2.  Radiation hazards to vascular surgeon and scrub nurse in mobile fluoroscopy equipped hybrid vascular room.

Authors:  Jong Bin Kim; Jaehoon Lee; Kihyuk Park
Journal:  Ann Surg Treat Res       Date:  2017-02-24       Impact factor: 1.859

3.  Pattern and degree of radiation exposure during endovascular surgery performed using a mobile C-arm or in a hybrid room.

Authors:  Cheng Quan; Sang Su Lee
Journal:  Ann Surg Treat Res       Date:  2018-02-26       Impact factor: 1.859

4.  Radiation - friend or foe? Presidential address to Ulster Medical Society 4th October 2012.

Authors:  Roy Spence
Journal:  Ulster Med J       Date:  2014-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.