Literature DB >> 19497444

Incidence, risk factors, and outcome of traumatic tricuspid regurgitation after percutaneous ventricular lead removal.

Frédéric Franceschi1, Franck Thuny, Roch Giorgi, Islem Sanaa, Eric Peyrouse, Xavier Assouan, Sébastien Prévôt, Emilie Bastard, Gilbert Habib, Jean-Claude Deharo.   

Abstract

OBJECTIVES: This study sought to evaluate the incidence, risk factors, and outcome of traumatic tricuspid regurgitation (TTR) induced by percutaneous removal of chronically implanted transvenous leads.
BACKGROUND: Although lead removal using modern tools has been shown to be highly effective and safe, TTR has not been systematically evaluated.
METHODS: All patients undergoing ventricular lead removal at our center were studied. Lead removal was performed by simple traction, laser sheath, and/or lasso technique. Presence of a new TTR after removal was assessed by transthoracic echocardiography. Pre-defined clinical and technical parameters were studied for their association with TTR. Patients were followed up by outpatient visits.
RESULTS: We removed 237 ventricular leads in 208 patients. Median time from lead implantation was 46.4 months (range 0.7 to 260.5 months). A TTR occurred in 19 patients (9.1%), severe in 14. Three independent risk factors of TTR were found: use of laser sheath (p = 0.004), use of both laser sheath and lasso (p = 0.02), and female sex (p = 0.02). After a follow-up of 4,130 person-months (median 17.9 months), 5 TTR patients were medically treated for new right-sided heart failure symptoms, 2 had undergone surgical repair of the tricuspid valve, and 6 had died (2 from heart failure and 4 from noncardiac causes). Right-sided heart failure occurred only in patients with severe TTR.
CONCLUSIONS: This study found that TTR is not uncommon after percutaneous lead removal. It is strongly associated with the use of additional tools beyond simple traction and also with female sex. In the long term, right-sided heart failure is frequent in patients with severe TTR.

Entities:  

Mesh:

Year:  2009        PMID: 19497444     DOI: 10.1016/j.jacc.2009.02.045

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  12 in total

1.  Treatment of Infected Cardiac Implantable Electronic Devices.

Authors:  Abdulla Fakhro; Faryan Jalalabadi; Rodger H Brown; Shayan A Izaddoost
Journal:  Semin Plast Surg       Date:  2016-05       Impact factor: 2.314

2.  Pacing lead extraction in the management of tricuspid regurgitation: a case report.

Authors:  Lynn Khor; Kedar Madan; Choon Huat Lee; Martin K C Ng
Journal:  Eur Heart J Case Rep       Date:  2022-05-17

3.  The role of cardiac surgery in transvenous lead extraction. A high-volume center experience with 3207 procedures.

Authors:  Łukasz Tułecki; Marek Czajkowski; Sylwia Targońska; Konrad Tomków; Dorota Nowosielecka; Wojciech Jacheć; Anna Polewczyk; Andrzej Kutarski
Journal:  Kardiochir Torakochirurgia Pol       Date:  2022-10-08

4.  The prognostic value of transesophageal echocardiography after transvenous lead extraction: landscape after battle.

Authors:  Dorota Nowosielecka; Wojciech Jacheć; Anna Polewczyk; Andrzej Kleinrok; Łukasz Tułecki; Andrzej Kutarski
Journal:  Cardiovasc Diagn Ther       Date:  2021-04

5.  Diagnosis of lead-induced tricuspid regurgitation.

Authors:  Stephan Wardell; Vikas Kuriachan; Sarah G Weeks; Israel Belenkie
Journal:  HeartRhythm Case Rep       Date:  2016-01-12

6.  Transjugular lead fragment extraction to improve tricuspid regurgitation.

Authors:  Robert D Schaller; Mouhannad M Sadek; Jeffrey J Luebbert; Jian-Fang Ren; Francis E Marchlinski
Journal:  HeartRhythm Case Rep       Date:  2015-02-13

7.  Transvenous lead extraction with laser reduces need for femoral approach during the procedure.

Authors:  Arwa Younis; Michael Glikson; Amit Meitus; Noga Arwas; Sharon Shalom Natanzon; Dor Lotan; David Luria; Roy Beinart; Eyal Nof
Journal:  PLoS One       Date:  2019-04-29       Impact factor: 3.240

8.  Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions.

Authors:  Mihai Strachinaru; Chris M Kievit; Sing C Yap; Alexander Hirsch; Marcel L Geleijnse; Tamas Szili-Torok
Journal:  Echocardiography       Date:  2019-03-24       Impact factor: 1.724

9.  Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients.

Authors:  Ji-Hoon Choi; Seung-Jung Park; Hye Ree Kim; Hee-Jin Kwon; Kyoung-Min Park; Young Keun On; June Soo Kim; Ju Youn Kim; Won Young Jung
Journal:  Sci Rep       Date:  2022-01-17       Impact factor: 4.379

10.  Unusual cause of hypoxemia after automatic implantable cardioverter-defibrillatorleads extraction.

Authors:  Dinesh Raju; Chandrika Roysam; Rajendra Singh; Stephen C Clark; Christopher Plummer
Journal:  Ann Card Anaesth       Date:  2015 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.