Literature DB >> 19494636

Endothelial evaluation in the cornea bank.

Jan Schroeter, Peter Rieck.   

Abstract

The light microscope is the first-choice technique for the evaluation of organ-cultured donor corneas. For the microscopic visualization of the endothelial cells, the corneas have to be immersed in ahypotonic solution. The number of cells, their vitality and morphology are analyzed. The cell densityis easily estimated with the fixed frame/L method. Use of an image analysis system enables computer processing and counting of digitalized endothelial cell images. An adequately high endothelial cell density after the culture period is a decisive criterion that must be met before releasing adonor cornea for grafting. An endothelial cell density of 2,000-2,200 cells/mm2 is generally recognized as the lower limit for the longest possible graft survival. While an evaluation of the endothelium does not necessarily have to be performed at the beginning or middle of organ culture, it isobligatory at the end. Morphology assessment should routinely involve estimating the pleomorphism (deviation from hexagonality), polymegathism (variation in cell area) and granulation/vacuolization of the endothelial cells. Recognition of devitalized cells is easily facilitated by vital stainingwith trypan blue. Copyright 2009 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2009        PMID: 19494636     DOI: 10.1159/000223838

Source DB:  PubMed          Journal:  Dev Ophthalmol        ISSN: 0250-3751


  3 in total

1.  Effect of basic fibroblast growth factor on cat corneal endothelial cell proliferation.

Authors:  Wen-Juan Luo; Yang Zhou; Mei-Guang Liu; Chuan-Fu Wang
Journal:  Int J Ophthalmol       Date:  2011-08-18       Impact factor: 1.779

2.  A novel human donor cornea preservation cocktail incorporating a thermo-reversible gelation polymer (TGP), enhancing the corneal endothelial cell density maintenance and explant culture of corneal limbal cells.

Authors:  Bhuvaneshwari Namitha; Munusamy Rajendran Chitra; Mathevan Bhavya; Periasamy Parikumar; Shojiro Katoh; Hiroshi Yoshioka; Masaru Iwasaki; Rajappa Senthilkumar; Mathaiyan Rajmohan; Ramalingam Karthick; Senthilkumar Preethy; Samuel J K Abraham
Journal:  Biotechnol Lett       Date:  2021-03-25       Impact factor: 2.461

3.  Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

Authors:  Jianyan Huang; Jyotsna Maram; Tudor C Tepelus; Cristina Modak; Ken Marion; SriniVas R Sadda; Vikas Chopra; Olivia L Lee
Journal:  J Optom       Date:  2017-08-07
  3 in total