Literature DB >> 19493395

Long-term efficacy of excimer laser in situ keratomileusis in the management of children with high anisometropic amblyopia.

Xiao-Ming Lin1, Xiao-He Yan, Zheng Wang, Bin Yang, Qi-Wen Chen, Jin-Ai Su, Xue-Lian Ye.   

Abstract

BACKGROUND: Children with anisometropic amblyopia are often noncompliant with traditional treatment including spectacules and contact lenses. This study was to evaluate the long-term efficacy of excimer laser in situ keratomileusis (LASIK) for children with high anisometropic amblyopia.
METHODS: A retrospective analysis of 24 children with high unilateral anisometropic amblyopia, who underwent LASIK during the period between August 2000 and September 2005 in our hospital, was conducted. The mean age of these children was (7.4 +/- 1.9) years (range 5 - 14 years) and the mean follow-up period was (33.3 +/- 14.2) months (range 18.5 - 74.2 months). After LASIK, visual acuity, refraction and far or near stereoacuity were analyzed. Near stereoacuity was measured by the random-dot butterfly stereogram and the pre-school random-dot stereogram, while far stereoacuity was measured by the synoptophore with Yan's random-dot stereogram.
RESULTS: Mean preoperative uncorrected visual acuity was 0.06 +/- 0.05, while mean postoperative uncorrected visual acuity was elevated to 0.43 +/- 0.33. Mean preoperative best-corrected visual acuity was 0.26 +/- 0.22, while mean postoperative best-corrected visual acuity was elevated to 0.67 +/- 0.40. For patients with myopic anisometropia, preoperative mean spherical equivalent refraction was (-8.01 +/- 2.70) D while postoperative value significantly reduced to (-1.32 +/- 2.47) D. For patients with hyperopic anisometropia, preoperative mean spherical equivalent refraction was (+7.35 +/- 1.55) D while postoperative value significantly reduced to (+3.30 +/- 0.86) D. These results demonstrated that there was statistical difference in these parameters between preoperative and postoperative tests. At the last follow-up, 20 patients had near stereoacuity, and the mean near stereoacuities measured by the random-dot butterfly stereogram and the preschool random-dot stereogram were (149.00 +/- 152.93)'' and (201.05 +/- 235.94)'', respectively. In contrast, 11 patients had far stereoacuity, and the mean far stereoacuity measured by the synoptophore was (210.91 +/- 217.51)''. Three cases of patients developed mild corneal complications.
CONCLUSION: LASIK for the correction of high anisometropia in children with monocular amblyopia may be safe and effective, and this can help effectively conduct postoperative amblyopia training and improve the cure rate.

Entities:  

Mesh:

Year:  2009        PMID: 19493395

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  7 in total

1.  Ocular aberrations in amblyopic children.

Authors:  Hind Ibrahem Aldebasi; Samah Mahmoud Fawzy; Ahmad A Alsaleh
Journal:  Saudi J Ophthalmol       Date:  2013-07-15

2.  Femtosecond laser corneal refractive surgery for the correction of high myopic anisometropic amblyopia in juveniles.

Authors:  Jing Zhang; Ke-Ming Yu
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

Review 3.  Stereopsis after corneal refractive surgeries: a systematic review and meta-analysis.

Authors:  Alireza Peyman; Mohsen Pourazizi; Mohamadreza Akhlaghi; Awat Feizi; Alireza Rahimi; Elham Soltani
Journal:  Int Ophthalmol       Date:  2022-01-18       Impact factor: 2.029

4.  Analysis of Macular and Retinal Nerve Fiber Layer Thickness in Children with Refractory Amblyopia after Femtosecond Laser-assisted Laser In situ Keratomileusis: A Retrospective Study.

Authors:  Peng-Fei Zhao; Yue-Hua Zhou; Jing Zhang; Wen-Bin Wei
Journal:  Chin Med J (Engl)       Date:  2017-09-20       Impact factor: 2.628

5.  Relative peripheral refraction across 4 meridians after orthokeratology and LASIK surgery.

Authors:  António Queirós; Ana Amorim-de-Sousa; Daniela Lopes-Ferreira; César Villa-Collar; Ángel Ramón Gutiérrez; José Manuel González-Méijome
Journal:  Eye Vis (Lond)       Date:  2018-05-20

6.  Corneal morphological changes after small incision lenticule extraction for myopic anisometropia.

Authors:  Lu Zhu; Yan Ji; Xin Yang; Xiaorong Lu; Qiong Wu; Qing Wang; Jiuyi Xia; Meng Li; Ke Hu; Wenjuan Wan
Journal:  Front Med (Lausanne)       Date:  2022-08-24

7.  The relationship between clinical measures of aniseikonia and stereoacuity before and after LASIK.

Authors:  Ivana Mravicic; Maja Bohac; Selma Lukacevic; Kruno Jagaric; Merlak Maja; Sudi Patel
Journal:  J Optom       Date:  2019-10-25
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.