Literature DB >> 19492714

The effect of storage conditions, contamination modes and cleaning procedures on the resin bond strength to lithium disilicate ceramic.

Karsten Klosa1, Stefan Wolfart, Frank Lehmann, Hans-Jürgen Wenz, Matthias Kern.   

Abstract

PURPOSE: The purpose of this in-vitro study was to evaluate the resin bond strength to pre-etched lithium disilicate ceramic using different cleaning methods after two contamination modes (saliva or saliva and silicone).
MATERIALS AND METHODS: Plexiglas tubes filled with composite resin (MultiCore Flow) were bonded to etched and silanized ceramic disks made of lithium disilicate ceramic (IPS e.max Press) using a luting resin (Multilink Automix). Either etched or unetched ceramic surfaces were contaminated with saliva or with saliva followed by a disclosing silicone. Groups of 16 specimens each were bonded after pretreatment using 4 surface cleaning agents (37% phosphoric acid, 5% hydrofluoric acid, 96% isopropanol, air polishing device with sodium bicarbonate) in different combinations. Before measuring tensile bond strength, specimens were stored for 3 or 150 days with thermocycling.
RESULTS: After 150 days of storage, etching of saliva-contaminated surfaces with 5% hydrofluoric acid and/or 37% phosphoric acid provided statistically significantly higher bond strengths (37.9 to 49.5 MPa) than the other cleaning methods (1.7 to 15.5 MPa). After saliva and silicone contamination, etching with 5% hydrofluoric acid provided statistically significantly higher bond strengths (44.5 to 50.3 MPa) than all other cleaning methods (0.3 to 13.5 MPa).
CONCLUSION: Ceramic cleaning methods after try-in procedures have a significant influence on the resin bond strength and are dependent on the type of contamination. Re-etching lithium disilicate ceramic with 5% hydrofluoric acid is most effective in removing contamination with saliva and/or a silicone disclosing medium.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19492714

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  8 in total

1.  Bond strength of composite resin to glass ceramic after saliva contamination.

Authors:  Frank Nikolaus; Martin Wolkewitz; Petra Hahn
Journal:  Clin Oral Investig       Date:  2012-06-23       Impact factor: 3.573

2.  Clinically used adhesive ceramic bonding methods: a survey in 2007, 2011, and in 2015.

Authors:  K Klosa; G Meyer; M Kern
Journal:  Clin Oral Investig       Date:  2015-12-04       Impact factor: 3.573

3.  The Influence of Different Surface Cleansing Agents on Shear Bond Strength of Contaminated Lithium Disilicate Ceramic: An In Vitro Study.

Authors:  Taksid Charasseangpaisarn; Pattarawadee Krassanairawiwong; Chanidapa Sangkanchanavanich; Atima Kurjirattikan; Kanyarak Kunyawatyuwapong; Natlada Tantivasin
Journal:  Int J Dent       Date:  2021-08-10

4.  Cleaning and Conditioning of Contaminated Core Build-Up Material before Adhesive Bonding.

Authors:  Karsten Klosa; Walid Shahid; Milda Aleknonytė-Resch; Matthias Kern
Journal:  Materials (Basel)       Date:  2020-06-26       Impact factor: 3.623

5.  Evaluation of the effect of silicone residue after different surface treatments on shear bond strength of glass ionomer cement to the dentin surface.

Authors:  R Anusha; M C Suresh Sajjan; A V Rama Raju; D Bheemalingeswararao; Nukalamarri Om Brahma Prasad Chary
Journal:  J Indian Prosthodont Soc       Date:  2019 Apr-Jun

6.  Adhesion of Resin to Lithium Disilicate with Different Surface Treatments before and after Salivary Contamination-An In-Vitro Study.

Authors:  Ryan Harouny; Louis Hardan; Elie Harouny; Cynthia Kassis; Rim Bourgi; Monika Lukomska-Szymanska; Naji Kharouf; Vincent Ball; Carlos Khairallah
Journal:  Bioengineering (Basel)       Date:  2022-06-29

7.  Assessment of Different Techniques for Adhesive Cementation of All-Ceramic Systems.

Authors:  Cristiana Cuzic; Marius Octavian Pricop; Anca Jivanescu; Sorin Ursoniu; Radu Marcel Negru; Mihai Romînu
Journal:  Medicina (Kaunas)       Date:  2022-07-27       Impact factor: 2.948

8.  UV-Mediated Photofunctionalization of Indirect Restorative Materials Enhances Bonding to a Resin-Based Luting Agent.

Authors:  Kyoko Ishikawa; Monica Yamauti; Antonin Tichy; Masaomi Ikeda; Takeshi Ueno; Noriyuki Wakabayashi; Ornnicha Thanatvarakorn; Taweesak Prasansuttiporn; Celso Afonso Klein-Junior; Akifumi Takahashi; Tomohiro Takagaki; Masatoshi Nakajima; Junji Tagami; Keiichi Hosaka
Journal:  Biomed Res Int       Date:  2021-05-29       Impact factor: 3.411

  8 in total