Literature DB >> 19492560

The use of a low-profile Ilizarov external fixator in the treatment of complex fractures and non-unions of the distal femur.

Ali Turgay Cavusoglu1, Mehmet Hakan Ozsoy, Veysel Ercan Dincel, Abdurrahman Sakaogullari, Kerem Basarir, Mahmut Ugurlu.   

Abstract

The aim of this study was to assess the effectiveness of a modified (low-profile) Ilizarov fixation in the treatment of complex fractures of the distal femur such asseptic or aseptic non-unions following previous surgeries, osteoporotic fractures, and high-grade open fractures. Ten male patients with a mean age of 50 years (range, 22-72 years) were treated with a modified Ilizarov fixator. The system was composed of tensioned olive wires attached to four 5/8 rings (two proximal and two distal to the fracture line) connected to each other with three rods. The fixator was not extended to the proximal femur nor across the knee to the tibia, and no Schanz screws were used. The main outcomes evaluated were union, time in fixator and IOWA knee score. Time in the fixator averaged 158 days (range, 125-180). Mean follow-up was 74 months (range, 24-108 months). All fractures united without major complications. One case healed with a 3 degrees varus angulation at the fracture site. The mean IOWA score was 83.8 (range, 70-98). Although superficial pin-tract infection was observed at 10 pin sites, no patient developed deep infection requiring premature pin removal. There was breakage of one wire, which was replaced under anaesthesia, and one patient presented a patella fracture after a fall, which healed after tension-band wire fixation. Considering the high union and low complication rates, we suggest the use of a low-profile Ilizarov fixator in the management of certain distal femoral fractures and non-unions that may be difficult to manage using other means of fixation.

Entities:  

Mesh:

Year:  2009        PMID: 19492560

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  8 in total

1.  Sequential reconstruction of complex femoral fractures with circular hybrid Sheffield frame in polytrauma patients.

Authors:  Francesco Sala; Tazio Talamonti; Maria Alice Agus; Dario Capitani
Journal:  Musculoskelet Surg       Date:  2010-11-27

2.  Comminuted distal femur closed fractures: a new application of the Ilizarov concept of compression-distraction.

Authors:  Ahmad El-Tantawy; Ashraf Atef
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-11-27

3.  Addition of a Medial Locking Plate to an In Situ Lateral Locking Plate Results in Healing of Distal Femoral Nonunions.

Authors:  Michael A Holzman; Bryan D Hanus; John W Munz; Daniel P O'Connor; Mark R Brinker
Journal:  Clin Orthop Relat Res       Date:  2016-01-21       Impact factor: 4.176

4.  Circular external fixation as definitive treatment for open or comminuted femoral fractures: Radiologic and functional outcomes.

Authors:  Giovanni Lovisetti; Rajesh Rohilla; Karan Siwach
Journal:  J Clin Orthop Trauma       Date:  2019-03-27

5.  Highly unstable complex C3-type distal femur fracture: can double plating via a modified Olerud extensile approach be a standby solution?

Authors:  Ayman El-Sayed Khalil; Mostafa Ahmed Ayoub
Journal:  J Orthop Traumatol       Date:  2012-06-26

6.  The use of twin-ring Ilizarov external fixator constructs: application and biomechanical proof-of principle with possible clinical indications.

Authors:  Theodoros B Grivas; Evangelos A Magnissalis
Journal:  J Orthop Surg Res       Date:  2011-08-11       Impact factor: 2.359

7.  Primary ilizarov external fixation in open grade III type C distal femur fractures: Our experience.

Authors:  Rakesh Kumar; Soumya Shrikanta Mohapatra; Narendra Joshi; S K Goyal; Kamlesh Kumar; Rajendra Gora
Journal:  J Clin Orthop Trauma       Date:  2019-01-30

8.  Efficacy of a compliant semicircular Ilizarov pin fixator module for treating infected nonunion of the femoral diaphysis.

Authors:  Ashraf A Khanfour; Mohamed M El-Sayed
Journal:  Strategies Trauma Limb Reconstr       Date:  2014-07-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.