Literature DB >> 19491441

Multi-frequency time-difference complex conductivity imaging of canine and human lungs using the KHU Mark1 EIT system.

Jihyeon Kuen1, Eung Je Woo, Jin Keun Seo.   

Abstract

We evaluated the performance of the lately developed electrical impedance tomography (EIT) system KHU Mark1 through time-difference imaging experiments of canine and human lungs. We derived a multi-frequency time-difference EIT (mftdEIT) image reconstruction algorithm based on the concept of the equivalent homogeneous complex conductivity. Imaging experiments were carried out at three different frequencies of 10, 50 and 100 kHz with three different postures of right lateral, sitting (or prone) and left lateral positions. For three normal canine subjects, we controlled the ventilation using a ventilator at three tidal volumes of 100, 150 and 200 ml. Three human subjects were asked to breath spontaneously at a normal tidal volume. Real- and imaginary-part images of the canine and human lungs were reconstructed at three frequencies and three postures. Images showed different stages of breathing cycles and we could interpret them based on the understanding of the proposed mftdEIT image reconstruction algorithm. Time series of images were further analyzed by using the functional EIT (fEIT) method. Images of human subjects showed the gravity effect on air distribution in two lungs. In the canine subjects, the morphological change seems to dominate the gravity effect. We could also observe that two different types of ventilation should have affected the results. The KHU Mark1 EIT system is expected to provide reliable mftdEIT images of the human lungs. In terms of the image reconstruction algorithm, it would be worthwhile including the effects of three-dimensional current flows inside the human thorax. We suggest clinical trials of the KHU Mark1 for pulmonary applications.

Entities:  

Mesh:

Year:  2009        PMID: 19491441     DOI: 10.1088/0967-3334/30/6/S10

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  A local region of interest imaging method for electrical impedance tomography with internal electrodes.

Authors:  Hyeuknam Kwon; Alistair L McEwan; Tong In Oh; Adnan Farooq; Eung Je Woo; Jin Keun Seo
Journal:  Comput Math Methods Med       Date:  2013-07-08       Impact factor: 2.238

2.  System Description and First Application of an FPGA-Based Simultaneous Multi-Frequency Electrical Impedance Tomography.

Authors:  Susana Aguiar Santos; Anne Robens; Anna Boehm; Steffen Leonhardt; Daniel Teichmann
Journal:  Sensors (Basel)       Date:  2016-07-25       Impact factor: 3.576

Review 3.  Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review.

Authors:  Tushar Kanti Bera
Journal:  J Med Eng       Date:  2014-06-17

Review 4.  A Review on Electrical Impedance Tomography Spectroscopy.

Authors:  Juliana Padilha Leitzke; Hubert Zangl
Journal:  Sensors (Basel)       Date:  2020-09-10       Impact factor: 3.576

5.  Electrical Impedance Tomography - Recent Applications and Developments.

Authors:  Sofiene Mansouri; Yousef Alharbi; Fatma Haddad; Souhir Chabcoub; Anwar Alshrouf; Amr A Abd-Elghany
Journal:  J Electr Bioimpedance       Date:  2021-11-20
  5 in total