Literature DB >> 19489595

Electrochemical immunochip sensor for aflatoxin M1 detection.

Charlie O Parker1, Yvonne H Lanyon, Mary Manning, Damien W M Arrigan, Ibtisam E Tothill.   

Abstract

An investigation into the fabrication, electrochemical characterization, and development of a microelectrode array (MEA) immunosensor for aflatoxin M(1) is presented in this paper. Gold MEAs (consisting of 35 microsquare electrodes with 20 microm x 20 microm dimensions and edge-to-edge spacing of 200 microm) together with on-chip reference and counter electrodes were fabricated using standard photolithographic methods. The MEAs were then characterized by cyclic voltammetry, and the behavior of the on-chip electrodes were evaluated. The microarray sensors were assessed for their applicability to the development of an immunosensor for the analysis of aflatoxin M(1) directly in milk samples. Following the sensor surface silanization, antibodies were immobilized by cross-linking with 1,4-phenylene diisothiocyanate (PDITC). Surface characterization was conducted by electrochemistry, fluorescence microscopy, scanning electron microscopy (SEM), and atomic force microscopy (AFM). A competitive enzyme linked immunosorbent assay (ELISA) assay format was developed on the microarray electrode surface using the 3,3,5',5'-tetramethylbenzidine dihyrochloride (TMB)/H(2)O(2) electrochemical detection scheme with horseradish peroxidase (HRP) as the enzyme label. The performance of the assay and the microarray sensor were characterized in pure buffer conditions before applying to the milk samples. With the use of this approach, the detection limit for aflatoxin M(1) in milk was estimated to be 8 ng L(-1), with a dynamic detection range of 10-100 ng L(-1), which meets present legislative limits of 50 ng L(-1). The milk interference with the sensor surface was also found to be minimal. These devices show high potential for development of a range of new applications which have previously only been detected using elaborate instrumentation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19489595     DOI: 10.1021/ac900511e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  13 in total

1.  Flow-through immunosensors using antibody-immobilized polymer monoliths.

Authors:  Jikun Liu; Chien-Fu Chen; Chih-Wei Chang; Don L DeVoe
Journal:  Biosens Bioelectron       Date:  2010-06-11       Impact factor: 10.618

Review 2.  Nanotechnology: current uses and future applications in the food industry.

Authors:  Muthu Thiruvengadam; Govindasamy Rajakumar; Ill-Min Chung
Journal:  3 Biotech       Date:  2018-01-13       Impact factor: 2.406

Review 3.  Microarray technology for major chemical contaminants analysis in food: current status and prospects.

Authors:  Zhaowei Zhang; Peiwu Li; Xiaofeng Hu; Qi Zhang; Xiaoxia Ding; Wen Zhang
Journal:  Sensors (Basel)       Date:  2012-07-04       Impact factor: 3.576

4.  Fluorimetric immunoassay for multianalysis of aflatoxins.

Authors:  Lizy Kanungo; Sunil Bhand
Journal:  J Anal Methods Chem       Date:  2013-08-13       Impact factor: 2.193

5.  Detection of the inflammation biomarker C-reactive protein in serum samples: towards an optimal biosensor formula.

Authors:  Wellington M Fakanya; Ibtisam E Tothill
Journal:  Biosensors (Basel)       Date:  2014-10-03

Review 6.  Recent Advances in Mycotoxin Determination for Food Monitoring via Microchip.

Authors:  Yan Man; Gang Liang; An Li; Ligang Pan
Journal:  Toxins (Basel)       Date:  2017-10-14       Impact factor: 4.546

7.  Label-Free and Redox Markers-Based Electrochemical Aptasensors for Aflatoxin M1 Detection.

Authors:  Stefanos Karapetis; Dimitrios Nikolelis; Tibor Hianik
Journal:  Sensors (Basel)       Date:  2018-12-01       Impact factor: 3.576

8.  Palladium Nanoparticles-Based Fluorescence Resonance Energy Transfer Aptasensor for Highly Sensitive Detection of Aflatoxin M₁ in Milk.

Authors:  Hui Li; Daibin Yang; Peiwu Li; Qi Zhang; Wen Zhang; Xiaoxia Ding; Jin Mao; Jing Wu
Journal:  Toxins (Basel)       Date:  2017-10-13       Impact factor: 4.546

9.  The Simultaneous Voltammetric Determination of Aflatoxins В1 and М1 on a Glassy-Carbon Electrode.

Authors:  G B Slepchenko; T M Gindullina; M A Gavrilova; A Zh Auelbekova
Journal:  J Anal Methods Chem       Date:  2018-05-09       Impact factor: 2.193

Review 10.  Optical Biosensors Based on Silicon-On-Insulator Ring Resonators: A Review.

Authors:  Patrick Steglich; Marcel Hülsemann; Birgit Dietzel; Andreas Mai
Journal:  Molecules       Date:  2019-01-31       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.