Literature DB >> 19488126

Tabletop soft-x-ray Fourier transform holography with 50 nm resolution.

R L Sandberg1, D A Raymondson, C La-O-Vorakiat, A Paul, K S Raines, J Miao, M M Murnane, H C Kapteyn, W F Schlotter.   

Abstract

We present what we believe to be the first implementation of Fourier transform (FT) holography using a tabletop coherent x-ray source. By applying curvature correction to compensate for the large angles inherent in high-NA coherent imaging, we achieve image resolution of 89 nm using high-harmonic beams at a wavelength of 29 nm. Moreover, by combining holography with iterative phase retrieval, we improve the image resolution to <53 nm. We also demonstrate that FT holography can be used effectively with short exposure times of 30 s. This technique will enable biological and materials microscopy with simultaneously high spatial and temporal resolution on a tabletop soft-x-ray source.

Year:  2009        PMID: 19488126     DOI: 10.1364/ol.34.001618

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  5 in total

1.  Optics: Ultrafast X-ray photography.

Authors:  Margaret M Murnane; Jianwei Miao
Journal:  Nature       Date:  2009-08-27       Impact factor: 49.962

2.  Nanoscale magnetic imaging using circularly polarized high-harmonic radiation.

Authors:  Ofer Kfir; Sergey Zayko; Christina Nolte; Murat Sivis; Marcel Möller; Birgit Hebler; Sri Sai Phani Kanth Arekapudi; Daniel Steil; Sascha Schäfer; Manfred Albrecht; Oren Cohen; Stefan Mathias; Claus Ropers
Journal:  Sci Adv       Date:  2017-12-15       Impact factor: 14.136

3.  Transverse Coherence Limited Coherent Diffraction Imaging using a Molybdenum Soft X-ray Laser Pumped at Moderate Pump Energies.

Authors:  M Zürch; R Jung; C Späth; J Tümmler; A Guggenmos; D Attwood; U Kleineberg; H Stiel; C Spielmann
Journal:  Sci Rep       Date:  2017-07-13       Impact factor: 4.379

4.  High resolution XUV Fourier transform holography on a table top.

Authors:  G K Tadesse; W Eschen; R Klas; V Hilbert; D Schelle; A Nathanael; M Zilk; M Steinert; F Schrempel; T Pertsch; A Tünnermann; J Limpert; J Rothhardt
Journal:  Sci Rep       Date:  2018-06-06       Impact factor: 4.379

5.  Real-time and sub-wavelength ultrafast coherent diffraction imaging in the extreme ultraviolet.

Authors:  M Zürch; J Rothhardt; S Hädrich; S Demmler; M Krebs; J Limpert; A Tünnermann; A Guggenmos; U Kleineberg; C Spielmann
Journal:  Sci Rep       Date:  2014-12-08       Impact factor: 4.379

  5 in total