Literature DB >> 19487769

High-quality cost-effective compound management support for HTS.

Maximiliano Zaragoza-Sundqvist1, Hans Eriksson, Mattias Rohman, Peter J Greasley.   

Abstract

Four years ago, the first acoustic droplet ejectors (ADEs) were launched on the market, providing a new generation of high-throughput noncontact liquid handlers that outclassed traditional contact instruments in almost every respect. This introduction of noncontact dispensing has triggered radical changes to the screening/compound management interface. Higher quality is achieved through greater accuracy and precision, whereas lower sample volumes can be used, and 1536 plate formats have become a reliable reality. Prior to the ADE instrument launch, 1536 assay-ready plate preparation was a high-effort enterprise requiring users to spend time developing liquid-handling methods along with daily fine-tuning of instruments to reach the desired level of performance. By overcoming the nanoliter dispensing hurdle and successfully transferring assays to high-density formats, a new dimension for cutting costs has emerged. Once the screening customer has adapted to this new world, the rules of supply can also change, with the traditional automated plate store no longer being necessary when the compound library can be stored in 1536 plates. Processing efficiency recently has been further supported by innovative new automation-friendly solutions such as plate desealers, prolonging the life span of working plate copies. Both cost and waste control have never had a higher profile, and noncontact dispensing contributes to these important areas. In some processes (e.g., when piercing septa), contact dispensing remains the best option, but cost control is still essential, and an innovative solution to minimize DMSO consumption from tip washing has had a big impact on consumable budget without compromising quality.

Entities:  

Mesh:

Year:  2009        PMID: 19487769     DOI: 10.1177/1087057109336589

Source DB:  PubMed          Journal:  J Biomol Screen        ISSN: 1087-0571


  2 in total

1.  Assessing HTS performance using BioAssay Ontology: screening and analysis of a bacterial phospho-N-acetylmuramoyl-pentapeptide translocase campaign.

Authors:  Andreas Moberg; Linda Zander Balderud; Eva Hansson; Helen Boyd
Journal:  Assay Drug Dev Technol       Date:  2014 Nov-Dec       Impact factor: 1.738

2.  Acoustic Droplet Ejection Technology and Its Application in High-Throughput RNA Interference Screening.

Authors:  N Miranda Nebane; Tatjana Coric; Sara McKellip; LaKeisha Woods; Melinda Sosa; Lynn Rasmussen; Mary-Ann Bjornsti; E Lucile White
Journal:  J Lab Autom       Date:  2015-12-09
  2 in total