Literature DB >> 19487740

Influence of patient head positioning on measured axial tooth inclination in panoramic radiography.

Timothy C Hardy1, Lokesh Suri, Paul Stark.   

Abstract

OBJECTIVE: Panoramic radiographs are routinely used to assess the mesiodistal axial inclination of teeth (MDAI) in orthodontic treatment. These radiographs are sensitive to minor deviations from standard head position that result in image distortions. The aim of this study is to measure and quantify the changes in MDAI on panoramic radiograph resulting from changes in patient head position.
MATERIALS AND METHODS: The testing devise was a human skull with guide wires placed on the facial surface of the teeth and alveolar process along the long axis of each tooth. Panoramic radiographs were captured digitally with the orientation of the skull in Frankfurt horizontal plane parallel to the floor and with 1 degrees , 2 degrees , 5 degrees , 7 degrees , and 10 degrees both superior and inferior rotations. The mesiodistal tooth angulations were determined using MIPAC software (DentalEye and LEAD Technologies, Inc. 2005).
RESULTS: The more distal the position of the tooth in the arch the greater the change in MDAI with a change in vertical head position. A maximum change of approximately 10 degrees was observed in MDAI of both the maxillary and mandibular molars with a corresponding superior head tilt of 10 degrees. The Mandibular anteriors displayed significant inconsistencies in MDAI with both superior and inferior head tilt. A superior head tilt produced a greater change in mesiodistal angulation than did an inferior head tilt.
CONCLUSIONS: Accurately taken panoramic radiographs can serve as a convenient tool for evaluating the MDAI before, during and after orthodontic treatment. Additional radiographs are recommended for the mandibular anteriors.

Entities:  

Mesh:

Year:  2009        PMID: 19487740     DOI: 10.1179/14653120723013

Source DB:  PubMed          Journal:  J Orthod        ISSN: 1465-3125


  8 in total

1.  The evaluation of MCI, MI, PMI and GT on both genders with different age and dental status.

Authors:  G Bozdag; S Sener
Journal:  Dentomaxillofac Radiol       Date:  2015-07-24       Impact factor: 2.419

2.  [Comparison of mesiodistal tooth angulations determined through traditional panoramic radiographs and cone beam CT panoramic images].

Authors:  Qiaoling Lei; Li Zhou; Lei Lei; Yanmin Wang
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2014-08

3.  Comparison of mesiodistal root angulation with posttreatment panoramic radiographs and cone-beam computed tomography.

Authors:  Daniel G Bouwens; Lucia Cevidanes; John B Ludlow; Ceib Phillips
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-01       Impact factor: 2.650

4.  Accuracy of Linear Measurements Using Cone Beam Computed Tomography in Comparison with Clinical Measurements.

Authors:  Amir Reza Rokn; Kazem Hashemi; Solmaz Akbari; Mohammad Javad Kharazifard; Hamidreza Barikani; Mehrdad Panjnoosh
Journal:  J Dent (Tehran)       Date:  2016-09

5.  Effect of mandibular first molar mesialization on alveolar bone height: a split mouth study.

Authors:  Nicolas Göllner; Jonas Winkler; Peter Göllner; Nikolaos Gkantidis
Journal:  Prog Orthod       Date:  2019-06-10       Impact factor: 2.750

6.  Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions.

Authors:  Sima Nikneshan; Mohamad Sharafi; Naghmeh Emadi
Journal:  Imaging Sci Dent       Date:  2013-09-23

7.  Comparison of the reproducibility of panoramic radiographs between dentulous and edentulous patients.

Authors:  Jong-Woong Park; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2014-06-11

8.  Evaluation of long-term stability of mesiodistal axial inclinations of maxillary molars through panoramic radiographs in subjects treated with Pendulum appliance.

Authors:  Caroline Andrade Rocha; Renato Rodrigues de Almeida; José Fernando Castanha Henriques; Carlos Flores-Mir; Marcio Rodrigues de Almeida
Journal:  Dental Press J Orthod       Date:  2016 Jan-Feb
  8 in total