Literature DB >> 19482392

Quantitative comparison of current models for trunk motion in human movement analysis.

Alberto Leardini1, Fabio Biagi, Claudio Belvedere, Maria Grazia Benedetti.   

Abstract

BACKGROUND: A number of different models for human trunk kinematics during locomotion have been proposed, though mainly addressing specific clinical questions rather than general populations. These differ considerably for the skeletal segments considered, marker-set, anatomical axis and frame definitions, and joint conventions. The scope of the present study is to compare quantitatively these models on the basis of the same motion.
METHODS: Ten subjects were analysed, instrumented with a single comprehensive marker-set of 14 markers identified from the union of the corresponding from eight current models for trunk kinematics. Activities of daily living (walking, chair rising/sitting, step-up/down), elementary trunk movements (flexion, bending and axial rotation), and isolated motion of the shoulders, both synchronous and asynchronous were collected. Resulting rotations in the three anatomical planes, both in the laboratory and in the pelvis reference frames, were calculated.
FINDINGS: In addition to the expected bias between the rotation angle time-histories, very different patterns and range of motion were found between the models. In chair rising/sitting, and in the laboratory global frame, the range of flexion averaged over the subjects was measured by the different models in the full scale from about 28 degrees to 44 degrees. In elementary trunk rotation and in the pelvis anatomical reference frame, three models measured about 10 degrees excursion of the coupled bending motion, other two about 38 degrees and 49 degrees on average.
INTERPRETATION: In trunk kinematics analysis, it is recommended that all models, both in terms of markers involved and of reference frame definitions, are understood carefully before interpreting the results in clinical decision making.

Entities:  

Mesh:

Year:  2009        PMID: 19482392     DOI: 10.1016/j.clinbiomech.2009.05.005

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  7 in total

1.  Factors affecting shoulder-pelvic integration during axial trunk rotation in subjects with recurrent low back pain.

Authors:  Woo-Hyung Park; Yoon Hyuk Kim; Tae Ro Lee; Paul S Sung
Journal:  Eur Spine J       Date:  2012-03-29       Impact factor: 3.134

2.  Effect of trunk sagittal attitude on shoulder, thorax and pelvis three-dimensional kinematics in able-bodied subjects during gait.

Authors:  Alberto Leardini; Lisa Berti; Mickaël Begon; Paul Allard
Journal:  PLoS One       Date:  2013-10-29       Impact factor: 3.240

3.  Clinically acceptable agreement between the ViMove wireless motion sensor system and the Vicon motion capture system when measuring lumbar region inclination motion in the sagittal and coronal planes.

Authors:  Hanne Leirbekk Mjøsund; Eleanor Boyle; Per Kjaer; Rune Mygind Mieritz; Tue Skallgård; Peter Kent
Journal:  BMC Musculoskelet Disord       Date:  2017-03-21       Impact factor: 2.362

4.  Synergy-Based Sensor Reduction for Recording the Whole Hand Kinematics.

Authors:  Néstor J Jarque-Bou; Joaquín L Sancho-Bru; Margarita Vergara
Journal:  Sensors (Basel)       Date:  2021-02-04       Impact factor: 3.576

5.  Trunk Posture from Randomly Oriented Accelerometers.

Authors:  Aidan R W Friederich; Musa L Audu; Ronald J Triolo
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

6.  Trunk motion and gait characteristics of pregnant women when walking: report of a longitudinal study with a control group.

Authors:  Wendy L Gilleard
Journal:  BMC Pregnancy Childbirth       Date:  2013-03-20       Impact factor: 3.007

7.  Trunk's natural inclination influences stance limb kinetics, but not body kinematics, during gait initiation in able men.

Authors:  Sébastien Leteneur; Emilie Simoneau; Christophe Gillet; Yoann Dessery; Franck Barbier
Journal:  PLoS One       Date:  2013-01-30       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.