Literature DB >> 19481367

[Ultrasound in the diagnosis of fetal head engagement. A preliminary French prospective study].

D Maticot-Baptista1, R Ramanah, A Collin, A Martin, R Maillet, D Riethmuller.   

Abstract

OBJECTIVE: The subjectivity and inter- and intra-observer variability of transvaginal (TV) digital examination in the diagnosis of fetal head engagement set a real problem in the strategic choice of the mode of delivery. We conducted a preliminary study on the feasibility of using ultrasound in the diagnosis of fetal head engagement during labour. MATERIAL AND
METHOD: From 3rd January to 20th February 2007, a prospective monocentered study was set up by comparing the fetal head position in the pelvic cavity obtained by TV digital examination with the ultrasound measurement of the perineum-fetal head distance. Sixty-five measurements were obtained from 45 patients (single pregnancies, cephalic presentations), during labour and/or at complete cervical dilatation, by a single operator.
RESULTS: Whenever the perineum-fetal head distance was greater than 60 mm, the fetal head was not engaged in the pelvic cavity, with a specificity of 89% and a negative predictive value of 94.1%. However, if the distance is less or equal to 60 mm, the fetal head was engaged with a sensitivity of 97.8% and a positive predictive value of 95.6%. It was even possible to define the fetal head station in the cavity as the distances are now known: high cavity : 50 mm, mid cavity : 38 mm, low cavity : 20 mm.
CONCLUSION: This technique based on a single distance measurement is not difficult and the reference point is easily localized. An abdominal probe is sufficient, making the diffusion of this method quite easy. With its excellent negative predictive value, transperineal ultrasound would allow obstetricians avoid difficult vaginal extractions, localize correctly the fetal position in the cavity and obtain the exact fetal head orientation, even in case of scalp blood humps. The feasibility and relevance of this technique must be confirmed by larger studies.

Entities:  

Mesh:

Year:  2009        PMID: 19481367     DOI: 10.1016/j.jgyn.2009.04.001

Source DB:  PubMed          Journal:  J Gynecol Obstet Biol Reprod (Paris)        ISSN: 0150-9918


  2 in total

Review 1.  The effectiveness of intrapartum  ultrasonography in assessing cervical dilatation, head station and position: A systematic review and meta-analysis.

Authors:  Yaw Amo Wiafe; Bill Whitehead; Heather Venables; Emmanuel Kweku Nakua
Journal:  Ultrasound       Date:  2016-10-06

2.  Sonographic parameters for diagnosing fetal head engagement during labour.

Authors:  Yaw A Wiafe; Bill Whitehead; Heather Venables; Alexander T Odoi
Journal:  Ultrasound       Date:  2018-02-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.