Literature DB >> 19481169

A pilot comparison of helium dilution and plethysmographic lung volumes to assess the impact of a long-acting bronchodilator on lung hyperinflation in COPD.

Mario Cazzola1, Paola Rogliani, Giacomo Curradi, Andrea Segreti, Chiara Ciaprini, Gabriella Pezzuto, Cesare Saltini.   

Abstract

BACKGROUND: Currently, two methods for measuring TLC, RV, and FRC are used in clinical pulmonary function laboratories: body plethysmography and helium dilution. However, these methods are not interchangeable. In moderate-to-severe airflow obstruction, dilution method tends to underestimate and body plethysmography tends to overestimate RV.
PURPOSE: In 21 patients suffering from COPD (basal FEV(1): 56.69+/-13.64), we investigated whether the two methods of measuring FRC and RV could respond differently to a 2-week treatment with tiotropium 18 microg/day. MAIN
RESULTS: Tiotropium induced a significant increase in FEV(1) and FVC but not in IC. At baseline, FRC(pleth), RV(pleth) and TLC(pleth) were higher than FRC(He), RV(He) and TLC(He). At the end of the study FRC(pleth), RV(pleth) and TLC(pleth) decreased and FRC(He), RV(He) and TLC(He) increased but only changes in FRC(pleth) and RV(pleth) were statistically significant.
CONCLUSION: The use of body plethysmography seems to be more appropriate in clinical trials aimed at assessing the impact of a therapeutic procedure in patients with COPD and lung hyperinflation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19481169     DOI: 10.1016/j.pupt.2009.05.005

Source DB:  PubMed          Journal:  Pulm Pharmacol Ther        ISSN: 1094-5539            Impact factor:   3.410


  3 in total

1.  The measurement of lung volumes using body plethysmography and helium dilution methods in COPD patients: a correlation and diagnosis analysis.

Authors:  Yongjiang Tang; Mingke Zhang; Yulin Feng; Binmiao Liang
Journal:  Sci Rep       Date:  2016-11-23       Impact factor: 4.379

2.  Flow-Volume Parameters in COPD Related to Extended Measurements of Lung Volume, Diffusion, and Resistance.

Authors:  Linnea Jarenbäck; Jaro Ankerst; Leif Bjermer; Ellen Tufvesson
Journal:  Pulm Med       Date:  2013-06-13

3.  Can the single-breath helium dilution method predict lung volumes as measured by whole-body plethysmography?

Authors:  Patrícia Chaves Coertjens; Marli Maria Knorst; Anelise Dumke; Adriane Schmidt Pasqualoto; João Riboldi; Sérgio Saldanha Menna Barreto
Journal:  J Bras Pneumol       Date:  2013 Nov-Dec       Impact factor: 2.624

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.