Epidural spinal cord compression with neurologic deficit associated with intrapedicular application of hemostatic gelatin matrix during pedicle screw insertion.

Jacob M Buchowski1, Keith H Bridwell, Lawrence G Lenke, Christopher R Good.   

Abstract

STUDY
DESIGN: Case report.
OBJECTIVE: In order to demonstrate the dangers of intrapedicular application of a hemostatic gelatin matrix to decrease blood loss during pedicle screw insertion, we present 2 patients who--as a result of inadvertent extravasation of the matrix into the spinal canal--developed epidural spinal cord compression (ESCC) requiring emergent decompression. SUMMARY OF BACKGROUND DATA: Variety of hemostatic agents can control bleeding during pedicle screw insertion. We have often used a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles by injecting the material into the pedicle after manually palpating the pedicle.
METHODS: Medical records and radiographic studies of 2 patients with AIS who underwent surgical treatment of their deformity and developed a neurologic deficit due to extravasation of FloSeal were reviewed.
RESULTS: A 15 year-old male underwent T4 to L2 posterior spinal fusion (PSF). During pedicle screw insertion, a change in NMEPs and SSEPs was noted. A wake-up test confirmed bilateral LE paraplegia. Screws were removed and no perforations were noted on manual palpation. MRI showed T7 to T10 ESCC. He underwent a T5 to T10 laminectomy and hemostatic gelatin matrix noted in the canal and was evacuated. He was ambulatory at 2 weeks and by 3 months he had complete recovery. The second patient was a 15 year-old female who underwent T4 to L1 PSF. Following screw insertion, deterioration in NMEPs and SSEPs was noted. Screws were removed and SCM data returned to baseline. Except for 3 screws that had an inferior breach (Left T7 and Bilateral T8), screws were reinserted and remainder of the surgery was uneventful. Postoperative examination was normal initially but 2 days later, she developed left LE numbness/weakness. Implants were removed and MRI showed T4 to T9 ESCC.She underwent a left (concave) T4 to T9 hemilaminectomy. Hemostatic gelatin matrix was noted and was evacuated. Six weeks following surgery, she had a complete neurologic recovery.
CONCLUSIONS: The use of a hemostatic gelatin matrix to decrease bleeding from cannulated pedicles during pedicle screw insertion can result in inadvertent extravasation into the spinal canal resulting in ESCC even in the absence of an apparent medial pedicle breach. Given the dangers associated with the technique, we recommend that gelatin matrix products be used judiciously during pedicle screw insertion.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19478651     DOI: 10.1097/BRS.0b013e3181a56a21

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  8 in total

1.  Bleeding control in pedicle subtraction osteotomy.

Authors:  Claudio Lamartina; Giovanni Casero
Journal:  Eur Spine J       Date:  2011-12       Impact factor: 3.134

2.  Surgical control of life-threatening post-ERCP bleeding with a gelatin matrix-thrombin hemostatic agent.

Authors:  Dimitrios Dimitroulis; Efstathios Antoniou; Nikolaos P Karidis; Konstantinos Kontzoglou; Gregory Kouraklis
Journal:  Int J Surg Case Rep       Date:  2012-06-02

3.  TETIS study: evaluation of new topical hemostatic agent TT-173 in tooth extraction.

Authors:  José López-López; Enric Jané-Salas; Amparo Santamaría; Beatriz González-Navarro; Carlos Arranz-Obispo; Ramón López; Ignasi Miquel; Belén Arias; Pilar Sánchez; Esther Rincón; Juan R Rodríguez; Santiago Rojas; Jesus Murat
Journal:  Clin Oral Investig       Date:  2015-09-15       Impact factor: 3.573

4.  A multi-center study of reoperations within 30 days of spine surgery.

Authors:  Takayoshi Shimizu; Shunsuke Fujibayashi; Mitsuru Takemoto; Bungo Otsuki; Hiroaki Kimura; Masato Ota; Akira Kusuba; Youngwoo Kim; Tsunemitsu Soeda; Kei Watanabe; Takeshi Sakamoto; Akira Uchikoshi; Naoya Tsubouchi; Shuichi Matsuda
Journal:  Eur Spine J       Date:  2015-07-14       Impact factor: 3.134

5.  Aphagia Strongly Suspected to Be Caused by an Allergic Reaction to a Gelatin-based Hemostatic Agent after Anterior Cervical Decompression and Fusion for Central Cervical Cord Injury.

Authors:  Satoshi Tanaka; Ryosuke Tomio; Norihiko Akao; Tsunemasa Shimizu; Toshio Ishikawa; Takeshi Fujimoto; Terumasa Nishimatsu
Journal:  NMC Case Rep J       Date:  2022-06-21

6.  Haemostatics in surgery and our experience in the enucleoresection of renal cell carcinoma.

Authors:  Gianna Pace; Pietro Saldutto; Carlo Vicentini; Lucio Miano
Journal:  World J Surg Oncol       Date:  2010-05-12       Impact factor: 2.754

7.  Degradable and Removable Tough Adhesive Hydrogels.

Authors:  Benjamin R Freedman; Oktay Uzun; Nadja M Maldonado Luna; Anna Rock; Charles Clifford; Emily Stoler; Gabrielle Östlund-Sholars; Christopher Johnson; David J Mooney
Journal:  Adv Mater       Date:  2021-03-24       Impact factor: 30.849

8.  Gelfoam-induced Swallowing Difficulty after Anterior Cervical Spine Surgery.

Authors:  Joo Chul Yang; Tae Wan Kim; Kwan Ho Park
Journal:  Korean J Spine       Date:  2013-06-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.