Abstract

The accuracy, reproducibility and reliability of CT-guided functional stereotaxis using Laitinen's Stereoadapter were assessed in 19 patients who underwent 14 thalamotomies and 5 pallidotomies for the treatment of essential tremor or Parkinson's disease. The coordinates of the target were obtained from a CT study with the Stereoadapter. At surgery, the Stereoadapter was remounted to the patient's head and the CT coordinates were transferred to Laitinen's Stereoguide without ventriculography. 3-12 months after surgery, a postoperative CT study with Stereoadapter was done. The coordinates of the stereotactic lesion were compared to the preoperative target coordinates. A new similar target was simulated on the postoperative CT study and its coordinates were compared to those of the preoperative target. The coordinates of the lesion versus preoperative target showed a maximal difference of 3.5 mm for the lateral (x-) coordinate, 3.5 mm for the anteroposterior (y-) coordinate, and 3.75 mm for the height (z-) coordinate. The differences were statistically significantly only for the x-coordinate: The lesions lay 1.25 mm, on the average, medial to the preoperative target. This medial displacement of the lesions was presumably due to a 10% inborn magnification error of the CT picture for the lateral direction. The maximal differences between the coordinates of the 'new' simulated target on the postoperative CT and those of the preoperative target were 2.5 mm for the x-, 2.25 mm for the y- and 3.75 mm for the z-coordinates. The differences were not statistically significant.

Entities:  

Mesh:

Year:  1991        PMID: 1947503     DOI: 10.1159/000099397

Source DB:  PubMed          Journal:  Stereotact Funct Neurosurg        ISSN: 1011-6125            Impact factor:   1.875


  2 in total

1.  Inter-racial, gender and aging influences in the length of anterior commissure-posterior commissure line.

Authors:  Tae-One Lee; Hyung-Sik Hwang; Antonio De Salles; Carlos Mattozo; Alessandra G Pedroso; Eric Behnke
Journal:  J Korean Neurosurg Soc       Date:  2008-02-20

2.  Air-ventriculography provokes an anterior displacement of the third ventricle during functional stereotactic procedures.

Authors:  M I Hariz; A T Bergenheim; H Fodstad
Journal:  Acta Neurochir (Wien)       Date:  1993       Impact factor: 2.216