Literature DB >> 19474120

Angiographic and histologic comparison of experimental aneurysms embolized with hydrogel filaments.

M Killer1, D F Kallmes, M R McCoy, Y-H Ding, J C Shum, G M Cruise.   

Abstract

BACKGROUND AND
PURPOSE: The embolization of aneurysms with hydrogel filaments allow postprocedural CT and MR imaging studies without artifacts. We compared the performance of 3 hydrogel filament formulations in rabbit experimental aneurysms by using angiography and histologic samples.
MATERIALS AND METHODS: Embolization of 35 rabbit elastase or bifurcation aneurysms was performed with 3 different formulations of detachable hydrogel filaments, including 1) polyethylene glycol opacified with aromatic iodine (PEG-I; n = 12), 2) polyethylene glycol opacified with barium sulfate (PEG-B; n = 12), or 3) polypropylene glycol opacified with barium sulfate (PPG-B; n = 11). Follow-up angiography was performed before the rabbits were killed at 2 (n = 7), 6 (n = 9), 10 (n = 8), or 26 (n = 11) weeks. Angiographic occlusion was scored according to the Raymond scale, and interval changes were assessed. The harvested aneurysms were evaluated on histologic examination. From the sections, we determined the percentage of the sac excluded from the vasculature and occupied by embolic devices by using image analysis. We compared results using the analysis of variance/t test or chi(2) test.
RESULTS: The mean number of devices used to treat aneurysms in the PPG-B group was significantly greater than that used for the other 2 groups, though aneurysm volumes were similar among groups. Compared with immediate posttreatment occlusion scores, mean angiographic occlusion at follow-up was increased for all 3 hydrogel filament groups. On histologic examination, thrombus organization, neointima formation, and inflammation were similar to that observed in rabbit experimental aneurysms with other embolic devices containing platinum coils.
CONCLUSIONS: The embolization of experimental aneurysms with hydrogel filaments resulted in durable angiographic and histologic occlusion from 2 to 26 weeks. With improvements, hydrogel filaments free from metallic coils show promise for endovascular use.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19474120     DOI: 10.3174/ajnr.A1649

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  10 in total

Review 1.  From bench to bedside: utility of the rabbit elastase aneurysm model in preclinical studies of intracranial aneurysm treatment.

Authors:  Waleed Brinjikji; Yong H Ding; David F Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2015-04-22       Impact factor: 5.836

2.  MR imaging of hydrogel filament embolic devices loaded with superparamagnetic iron oxide or gadolinium.

Authors:  Monika Killer; Edward M Keeley; Gregory M Cruise; Anne Schmitt; Mark R McCoy
Journal:  Neuroradiology       Date:  2010-07-13       Impact factor: 2.804

3.  Large animals in neurointerventional research: A systematic review on models, techniques and their application in endovascular procedures for stroke, aneurysms and vascular malformations.

Authors:  Andrea M Herrmann; Stephan Meckel; Matthew J Gounis; Leona Kringe; Edith Motschall; Christoph Mülling; Johannes Boltze
Journal:  J Cereb Blood Flow Metab       Date:  2019-02-07       Impact factor: 6.200

4.  Creation of bifurcation-type elastase-induced aneurysms in rabbits.

Authors:  Y H Ding; R Kadirvel; D Dai; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-08       Impact factor: 3.825

5.  The Woven EndoBridge: a new aneurysm occlusion device.

Authors:  Y H Ding; D A Lewis; R Kadirvel; D Dai; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2011-02-17       Impact factor: 3.825

6.  Creation of large elastase-induced aneurysms: presurgical arterial remodeling using arteriovenous fistulas.

Authors:  Y Ding; D Dai; R Kadirvel; D A Lewis; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

7.  Monitoring of the heparinization in the rabbit animal model during endovascular interventions.

Authors:  Anne J Schmitt; Anna K Wallner; Shahrzad Afazel; Monika Killer-Oberpfalzer
Journal:  Neuroradiology       Date:  2013-04-26       Impact factor: 2.804

8.  Angiographic and artefact-free computed tomography imaging of experimental aneurysms embolised with hydrogel filaments.

Authors:  Mark R McCoy; Gregory M Cruise; Monika Killer
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

9.  Experimental testing of the dual-layer Woven EndoBridge device using an elastase-induced aneurysm model in rabbits.

Authors:  Yong-Hong Ding; Daying Dai; Dana Schroeder; Ramanathan Kadirvel; David F Kallmes
Journal:  Interv Neuroradiol       Date:  2016-02-03       Impact factor: 1.610

10.  Rabbit aneurysm models mimic histologic wall types identified in human intracranial aneurysms.

Authors:  Shunli Wang; Daying Dai; Praveen Kolumam Parameswaran; Ramanathan Kadirvel; Yong-Hong Ding; Anne M Robertson; David F Kallmes
Journal:  J Neurointerv Surg       Date:  2017-08-02       Impact factor: 5.836

  10 in total