Bladder and rectal dose of gynecologic high-dose-rate implants: comparison of orthogonal radiographic measurements with in vivo and CT-assisted measurements.

G F Stuecklschweiger1, K S Arian-Schad, E Poier, J Poschauko, A Hackl.   

Abstract

Bladder and rectal doses were retrospectively reviewed in 281 patients who underwent implantation of 575 gynecologic iridium-192 high-dose-rate devices. Dose measurements obtained with orthogonal radiography, in vivo thermoluminescent dosimetry, and computed tomography (CT)-assisted planning were compared. Measurements of bladder dose derived from radiographs revealed a significant difference between bladder neck dose and bladder base dose (P less than .0001). In 17% of cases, the dose to the bladder base was at least double the dose to the bladder neck. The mean dose to the rectum calculated from radiographs was 85.9% (cervix) and 90.2% (vaginal vault) of the prescribed fraction dose. The correlation coefficient factor between doses determined with orthogonal radiographs and doses determined with in vivo measurements was .9694. The dose to the bladder neck and to four rectal points determined with corresponding CT images revealed a deviation of 4% and 7%, respectively. However, calculations at the rectal wall cephalic to the specified rectal points showed higher doses to the rectum, with a ratio of 1-1.6. CT-assisted calculations at the bladder base also revealed doses that were higher than those obtained with radiographs alone by a ratio of 1.4-2.2. CT-assisted dosimetry is the method of choice.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1947116     DOI: 10.1148/radiology.181.3.1947116

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

Review 1.  Image-based brachytherapy for cervical cancer.

Authors:  John A Vargo; Sushil Beriwal
Journal:  World J Clin Oncol       Date:  2014-12-10

2.  The consistency of Fletcher-Suit applicator geometry and of the rectal probe's position in high dose rate brachytherapy treatment fraction of cervix carcinoma.

Authors:  Jenő Pálvölgyi
Journal:  J Contemp Brachytherapy       Date:  2009-10-08

3.  Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector.

Authors:  Singh N; Ahamed S; Sinha A; Srivastava S; Painuly N K; Mandal A; Prasad S N
Journal:  J Biomed Phys Eng       Date:  2020-04-01