| Literature DB >> 19467818 |
Ding Yang1, Chen Yu, Shuijun Li, Gangyi Liu, Youli Lu, Yiping Wang.
Abstract
A sensitive and specific LC-CMS/MS method was developed for the quantification of changrolin, an anti-arrhythmic drug, in rat plasma using tiapride as internal standard. Liquid-liquid extraction was employed for sample preparation and analyzed using a multiple reaction monitoring mode with electrospray positive ionization source. The calibration curve for changrolin was linear over the range 5-1600 ng/mL with coefficients of correlation >0.99. The intra- and inter-batch precision was less than 8.6%, and accuracy ranged from 94.6% to 104.5%. This validated LC-MS/MS method was successfully applied to a bioavailability study of oral and intravenous administration of changrolin with 20mg/kg dosage in SD rats.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19467818 DOI: 10.1016/j.jpba.2009.04.010
Source DB: PubMed Journal: J Pharm Biomed Anal ISSN: 0731-7085 Impact factor: 3.935