Multimodality fusion imaging using delayed-enhanced cardiac magnetic resonance imaging, computed tomography, positron emission tomography, and real-time intracardiac echocardiography to guide ventricular tachycardia ablation in implantable cardioverter-defibrillator patients.

Jing Tian1, Mark F Smith, Jean Jeudy, Timm Dickfeld.   

Abstract

Entities:  

Mesh:

Year:  2009        PMID: 19467512     DOI: 10.1016/j.hrthm.2009.02.032

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


× No keyword cloud information.
  7 in total

Review 1.  Fusion of imaging technologies: how, when, and for whom?

Authors:  Ashul Govil; Hugh Calkins; David D Spragg
Journal:  J Interv Card Electrophysiol       Date:  2011-10-01       Impact factor: 1.900

Review 2.  Use of imaging techniques to guide catheter ablation procedures.

Authors:  Melissa R Robinson; Mathew D Hutchinson
Journal:  Curr Cardiol Rep       Date:  2010-09       Impact factor: 2.931

3.  Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators.

Authors:  Takeshi Sasaki; Rozann Hansford; Menekhem M Zviman; Aravindan Kolandaivelu; David A Bluemke; Ronald D Berger; Hugh Calkins; Henry R Halperin; Saman Nazarian
Journal:  Circ Cardiovasc Imaging       Date:  2011-09-23       Impact factor: 7.792

4.  Fusion of Three-Dimensional Echocardiographic Regional Myocardial Strain with Cardiac Computed Tomography for Noninvasive Evaluation of the Hemodynamic Impact of Coronary Stenosis in Patients with Chest Pain.

Authors:  Victor Mor-Avi; Mita B Patel; Francesco Maffessanti; Amita Singh; Diego Medvedofsky; S Javed Zaidi; Anuj Mediratta; Akhil Narang; Noreen Nazir; Nadjia Kachenoura; Roberto M Lang; Amit R Patel
Journal:  J Am Soc Echocardiogr       Date:  2018-03-22       Impact factor: 5.251

5.  Hemodynamic impact of coronary stenosis using computed tomography: comparison between noninvasive fractional flow reserve and 3D fusion of coronary angiography with stress myocardial perfusion.

Authors:  Amit R Patel; Francesco Maffessanti; Mita B Patel; Kalie Kebed; Akhil Narang; Amita Singh; Diego Medvedofsky; S Javed Zaidi; Anuj Mediratta; Neha Goyal; Nadjia Kachenoura; Roberto M Lang; Victor Mor-Avi
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-09       Impact factor: 2.357

6.  Imaging-guided Ventricular Tachycardia Ablation.

Authors:  Sebastiaan Rd Piers; Katja Zeppenfeld
Journal:  Arrhythm Electrophysiol Rev       Date:  2013-11-29

7.  Non-invasive assessment of the haemodynamic significance of coronary stenosis using fusion of cardiac computed tomography and 3D echocardiography.

Authors:  Francesco Maffessanti; Amit R Patel; Mita B Patel; James J Walter; Anuj Mediratta; Diego Medvedofsky; Nadjia Kachenoura; Roberto M Lang; Victor Mor-Avi
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2017-06-01       Impact factor: 6.875