Literature DB >> 19466161

Interpolation strategies for reducing IFOV artifacts in microgrid polarimeter imagery.

Bradley M Ratliff1, Charles F LaCasse, J Scott Tyo.   

Abstract

Microgrid polarimeters are composed of an array of micro-polarizing elements overlaid upon an FPA sensor. In the past decade systems have been designed and built in all regions of the optical spectrum. These systems have rugged, compact designs and the ability to obtain a complete set of polarimetric measurements during a single image capture. However, these systems acquire the polarization measurements through spatial modulation and each measurement has a varying instantaneous field-of-view (IFOV). When these measurements are combined to estimate the polarization images, strong edge artifacts are present that severely degrade the estimated polarization imagery. These artifacts can be reduced when interpolation strategies are first applied to the intensity data prior to Stokes vector estimation. Here we formally study IFOV error and the performance of several bilinear interpolation strategies used for reducing it.

Entities:  

Mesh:

Year:  2009        PMID: 19466161     DOI: 10.1364/oe.17.009112

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  7 in total

1.  New diagonal micropolarizer arrays designed by an improved model in fourier domain.

Authors:  Jia Hao; Yan Wang; Kui Zhou; Xiaochang Yu; Yiting Yu
Journal:  Sci Rep       Date:  2021-03-11       Impact factor: 4.379

2.  Snapshot linear-Stokes imaging spectropolarimeter using division-of-focal-plane polarimetry and integral field spectroscopy.

Authors:  Tingkui Mu; Shaun Pacheco; Zeyu Chen; Chunmin Zhang; Rongguang Liang
Journal:  Sci Rep       Date:  2017-02-13       Impact factor: 4.379

3.  Residual Interpolation Integrated Pixel-by-Pixel Adaptive Iterative Process for Division of Focal Plane Polarimeters.

Authors:  Jie Yang; Weiqi Jin; Su Qiu; Fuduo Xue; Meishu Wang
Journal:  Sensors (Basel)       Date:  2022-02-16       Impact factor: 3.576

4.  Dual division of focal plane polarimeters-based collinear reflection Mueller matrix fast imaging microscope.

Authors:  Tongyu Huang; Ruoyu Meng; Jiawei Song; Tongjun Bu; Yuanhuan Zhu; Migao Li; Ran Liao; Hui Ma
Journal:  J Biomed Opt       Date:  2022-08       Impact factor: 3.758

Review 5.  Bio-inspired polarized skylight-based navigation sensors: a review.

Authors:  Salmah B Karman; S Zaleha M Diah; Ille C Gebeshuber
Journal:  Sensors (Basel)       Date:  2012-10-24       Impact factor: 3.576

6.  Survey of Demosaicking Methods for Polarization Filter Array Images.

Authors:  Sofiane Mihoubi; Pierre-Jean Lapray; Laurent Bigué
Journal:  Sensors (Basel)       Date:  2018-10-30       Impact factor: 3.576

7.  Bioinspired Polarization Imaging Sensors: From Circuits and Optics to Signal Processing Algorithms and Biomedical Applications: Analysis at the focal plane emulates nature's method in sensors to image and diagnose with polarized light.

Authors:  Timothy York; Samuel B Powell; Shengkui Gao; Lindsey Kahan; Tauseef Charanya; Debajit Saha; Nicholas W Roberts; Thomas W Cronin; Justin Marshall; Samuel Achilefu; Spencer P Lake; Baranidharan Raman; Viktor Gruev
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2014-08-20       Impact factor: 10.961

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.