Literature DB >> 19463313

Abnormal vasomotor function of porcine coronary arteries distal to sirolimus-eluting stents.

Jinsheng Li1, Refat Jabara, Lakshmana Pendyala, Yoritaka Otsuka, Toshiro Shinke, Dongming Hou, Keith Robinson, Nicolas Chronos.   

Abstract

OBJECTIVES: This study sought to determine vasomotor functional responses of conduit coronary artery distal to bare-metal stents (BMS), polymer-only stents (POLY), and sirolimus-eluting stents (SES) in a clinically relevant animal model.
BACKGROUND: Drug-eluting stents (DES) reduce in-stent restenosis, and also affect neointima formation and vascular remodeling in downstream coronary segments. Whether distal artery vasomotor function is also influenced by DES has not been determined.
METHODS: Pigs (n = 12) received coronary stent implants, and hearts were harvested at 1 month. Arterial segments >or=15 mm distal to stents were excised and studied in an organ-chamber apparatus. Endothelium-dependent and endothelium-independent relaxation and contraction to classical agonists were measured.
RESULTS: The SES showed increased lumen area and reduced neointima; abnormal vasomotor function of conduit arteries distal to SES also was observed. Contraction to endothelin-1 was significantly enhanced for SES compared with both BMS and POLY. Endothelium-dependent relaxation to a maximal dose of substance P was attenuated for SES compared with both BMS and POLY (46 +/- 6% vs. 71 +/- 3% and 78 +/- 3%, respectively, p < 0.001). Endothelium-independent relaxation to sodium nitroprusside was potentiated for SES, compared with BMS and POLY (100 +/- 5% vs. 69 +/- 7% and 77 +/- 5%, respectively, p = 0.02).
CONCLUSIONS: Stent-based local delivery of sirolimus profoundly inhibited neointima formation but caused vasomotor dysfunction in distal conduit vessel segments. These observations suggest that distal coronary vasospasm may be more readily evoked in the presence of DES and contribute to pathophysiological sequela.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19463313     DOI: 10.1016/j.jcin.2008.01.009

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  7 in total

1.  Late stent thrombosis, endothelialisation and drug-eluting stents.

Authors:  G Ertaş; H M van Beusekom; W J van der Giessen
Journal:  Neth Heart J       Date:  2009-04       Impact factor: 2.380

Review 2.  Effects of Catheterization on Artery Function and Health: When Should Patients Start Exercising Following Their Coronary Intervention?

Authors:  Andrea Tryfonos; Daniel J Green; Ellen A Dawson
Journal:  Sports Med       Date:  2019-03       Impact factor: 11.136

3.  Assessment of an asymmetrical coating stent with sirolimus released from ablumial matrix in porcine model.

Authors:  Li Shen; Yizhe Wu; Feng Zhang; Lingxiang Wu; Chao Dong; Yongxing Gao; Aijun Sun; Yunzeng Zou; Juying Qian; Jianguo Sun; Wei Zhong; Junbo Ge
Journal:  Clin Res Cardiol       Date:  2012-05-25       Impact factor: 5.460

4.  Evaluation and medical therapy for coronary endothelial dysfunction induced by sirolimus-eluting stent in patient with an atherosclerotic lesion of the left main coronary artery: Case report.

Authors:  Hiroyuki Tabata; Satoshi Yoshino; Kenta Ohmure; Daichi Fukumoto; Hirokazu Shimono; Yoshihiro Uchikado; Shigeki Tateishi; Mitsuru Ohishi
Journal:  J Cardiol Cases       Date:  2017-09-22

5.  Comparison of bare metal stent and paclitaxel-eluting stent using a novel rat aorta stent model.

Authors:  Jin Sook Kwon; Rho Kwan Park; Tae Jin Shim; Myung Ho Jeong; Myeong Chan Cho; Youngkeun Ahn; Dong-Woon Kim
Journal:  J Vet Sci       Date:  2011-06       Impact factor: 1.672

6.  Accelerated Recovery of Endothelium Function after Stent Implantation with the Use of a Novel Systemic Nanoparticle Curcumin.

Authors:  Qi Lu; Fang Ye; Xiangjun Yang; Qingqing Gu; Peng Wang; Jianhua Zhu; Li Shen; Feirong Gong
Journal:  Biomed Res Int       Date:  2015-06-08       Impact factor: 3.411

7.  Anti-inflammatory effects of arsenic trioxide eluting stents in a porcine coronary model.

Authors:  Li Shen; Feirong Gong; Wenjie Tian; Weiming Li; Feng Zhang; Juying Qian; Aijun Sun; Yunzeng Zou; Wei Yang; Junbo Ge
Journal:  Biomed Res Int       Date:  2013-01-16       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.